Appendix B: Specifications
SolarEdge Installation Guide - MAN-01-00060-2.6
62
sE2200
SE3000 SE3500 SE4000 SE4000
- 16A
SE5000 SE6000 Unit
Maximum input voltage
500
Vdc
nominal DC input voltage
350
Vdc
Maximum Input Current
8.5
11.5
13.5
15.5
15.5
19.5
23
adc
Maximum recharge current
0
adc
Protection against polarity
reversal
Yes
Grounding fault detection
Sensitivity 600 kOhms
Category against
overvoltage
III
maximum efficiency of the inverter
97.6
%
European Weighted
Efficiency
97.6
97.6
1
97.6
1
97.5
97.5
97.5
97.4
97.4
%
night consumption
<2.5
W
features surcharges ents
features surcharges ents
interfaces
Communication supported
RS485, RS232, Ethernet, ZigBee (optional)
Standard Compliant s
Standard Compliant s
security
IEC-62103 (EN50178), IEC-62109 project
Network connection Standards
VDE-AR-N-4105, VDE 0126-1-1, AS-4777, DR-1663, DK 5940
emissions
IEC61000-6-2, CEI61000-6-3, IEC61000-3-11, IEC61000-3-12,
FCC Part 15 Class B
Compliant
Yes
Specifications Washroom we
Specifications Washroom we
AC output
Diameter press étoupe9-16
mm
DC input
1 pair of MC4
2 pairs of MC4
Dimensions (L x W x H)
540 X 315 x 172
540 X 315 x 191
mm
Weight
2 .2
21.7
kg
Cooling
Natural convection
Noise (typical)
<50
DBA
Operating temperature range
2
Operating temperature range
2
-20-50 (M40 version of -40 to + 50)
° C
1
97.5 SE3000 with the AC current limit 16A
1
97.5 SE3000 with the AC current limit 16A
2
For the UPS power derating see the application note at
http://www.solaredge.com/files/pdfs/se-temperature-derating-note.pdf
2
For the UPS power derating see the application note at
http://www.solaredge.com/files/pdfs/se-temperature-derating-note.pdf
2
For the UPS power derating see the application note at
http://www.solaredge.com/files/pdfs/se-temperature-derating-note.pdf