background image

SAFETY, INSTALLATION, AND OPERATIONS MANUAL 

© The Solaria Corporation 

Contents subject to change without notice.

U.S. and International patents issued and pending  

Document PSC-0004 Rev 02, November 2010

11 of 12

 

8.

  FRAMELESS MECHANICAL SPECIFICATIONS:

z

Frameless Module Weight: 29 kg (65 lbs)

4-color

2-color

1-color

4-color

1-color

Summary of Contents for 210W

Page 1: ...color color color color color Solaria Frameless 230W 220W 210W Module Series Mono crystalline Solar Panels 156x156mm Cells SAFETY INSTALLATION AND OPERATIONS MANUAL North America and Europe...

Page 2: ...igher than 240W where general contact access is anticipated modules qualified for safety through EN IEC 61730 1 and 2 within this application class are considered to meet the requirements for Safety C...

Page 3: ...HE FOLLOWING PRECAUTIONS TO AVOID FIRE HAZARDS Refer to your local authority for guidelines and requirements for building and structural fire safety The roof construction and installation may affect t...

Page 4: ...the module label Connection cables and wiring must be supported with cable ties and clips to the module support structures DO NOT use module junction boxes to support cables and wiring Under normal c...

Page 5: ...module in a string of modules causes reverse voltage across the shaded cells This results in current being forced through the shaded cells causing module heating and severe power loss The bypass diode...

Page 6: ...he application z z Clearance of 7mm or more between frameless modules is required to allow for thermal expansion of the tracker rack mounting hardware z z The back surface of the module must always be...

Page 7: ...mm from the edge See following figure for allowed clip locations Note the following z z For each module use four sets of stainless steel hardware each set 5 16 18 hex head bolt at 8mm diameter hex nut...

Page 8: ...nses are in the North South direction This orientation is called Landscape Mount It positions the cell lenses parallel to the axis of rotation z z Dual Axis Tracker Modules should be tracker open rack...

Page 9: ...or expense arising out of or in any connection with such installation operation use or maintenance of the modules z z The Solaria Corporation assumes no responsibility for any infringement of patents...

Page 10: ...3 81 Current at Pmax A 6 71 6 46 6 21 Cells Monocrystalline Bypass Diodes 5 1 per String 5 Strings Ratings 15 Amps each Max Vrrm 45 Volts Type ZJRH PVS105 Isc 3 10 mA C Imp 4 10 mA C Voc 166 5 mV C Vm...

Page 11: ...Solaria Corporation Contents subject to change without notice U S and International patents issued and pending Document PSC 0004 Rev 02 November 2010 11 of 12 8 FRAMELESS MECHANICAL SPECIFICATIONS z z...

Page 12: ...t CA 94555 United States of America T 1 510 270 2500 F 1 510 793 8388 Solaria Germany Oranienburger Strasse 23 D 10178 Berlin Germany T 40 30 233 297 97 F 49 30 275 748 56 Solaria India 202 SSH Pride...

Reviews: