The working principle of units

  

PHNIX moonlight treasure box series--Ultra-thin fan-coil unit in which water and cooling, 

heating medium of a new generation of air terminal product, ultra-thin with cooling and heating 
function, can apply to the room refrigeration, desiccant and heating

fig.3

.

    

And the traditional fan-coil PHNIX compared ultra-thin fan coil, thinner, is more static, the 

more beautiful; The ultra-thin design meticulously PHNIX fan-coil every broke traditional fan 
coil installation modes, may realize the vertical, horizontal, hang wall and so on many kinds 
of installation, sharply reduced installation cost.

3.4  Unit characteristics

(1) Ultra-low mute
Using low noise tubular fan, combining advanced ventilation technology on internal exquisite 
layout, let the machine low db operation, let you sleep more comfortable
(2)Ultra-thin design
Internal parts ultra-thin precision contact, thickness, compared to the normal vertical 
9.84inch thickness of the disk, PHNIX 5.12inch ultra-thin fan coil only the width, and palm, vie 
for you leave more valuable space.
(3)Appearance fashion
The appearance of the radian of noble fashion,white colour elegant and easy, no matter in any
one place, will indoor become beautiful scenery.
(4)Using a new design of vertical wind disk controller, appearance vogue, interface 
contracted,operating more simple, more human nature.

Fig.3

Water inlet

cooling (or heating) 

Water outlet

Air flow

3.Specification

5.2  Usage of wire controlle

2.1 Temperature setting

When on the main interface of heating, cooling and automatic mode, you can press 

       

or

       

once to check the setting temperature. Press 

        

or

        

 again to increase or 

decrease the setting temperature. Press

        

,

        

or ON/OFF button to change mode, 

wind speed or shutdown the unit and save settings.

Note: System will save user's setting and return back to main interface if there is no operation

 on buttons in 5 seconds.

        

or

        

 is invalid when the unit is in ventilating mode or dehumidifying mode.

M

M

HEAT

COOL

HIGH

LOW

MID

M

M

Indoor ambient temperature

HEAT

COOL

HIGH

LOW

MID

M

M

Press

     

or

     

to check the setting 
temperature of 
current mode.

Set temperature in heating mode

Press

     

or

     

to set the setting 
temperature of 
current mode.

12

5.Usage

Summary of Contents for Vertical Fan Coil

Page 1: ...Vertical Fan Coil Vertical Fan Coil Installation and Maintenance Manual Installation and Maintenance Manual Code 20110615 0001 ...

Page 2: ...er table Maintenance and Overhaul Preventive and Maintenance Common fault and the solving methods Appendix Controller of motherboard interface diagram 2 1 Mark Notes 2 2 Icon Notes 2 3 2 4 3 3 1 3 2 3 3 3 4 4 4 1 4 2 4 3 4 4 5 5 1 5 2 5 3 5 4 5 5 6 6 1 6 2 7 7 1 1 2 2 2 2 3 4 4 4 5 5 6 6 6 8 10 11 11 13 14 15 15 17 17 16 16 16 NO 1 2 3 4 5 6 7 8 9 Signal CN4 CN5 CN7 FAN TEMP N OUT L N PE meaning F...

Page 3: ...165mm 165mm 165mm 165mm 025 100 025 100 90 90 165mm 165mm 165mm 165mm 025 100 025 100 025 040 060 080 100 025 040 060 080 100 mm 0 200 400 600 800 mm 0 200 400 600 800 90 90 025 040 060 080 100 025 040 060 080 100 mm 0 200 400 600 800 mm 0 200 400 600 800 2 8 2 8 TEMP MODE FAN ON OFF PM10 50 0 00 UNIVERSAL A C REMOTE Screw cap Vertical Water Fan Coil INSTALLATION AND MAINTENANCE MANUAL electrother...

Page 4: ...se entrust dealer or qualified person to carry it out Improper movement or repair on the unit will lead to water leakage electrical shock injury or fire MOVE AND REPAIR ENTRUST ENTRUST PROHIBIT 2 1 Mark Notes 1 The injury means no need to be in hospital and cure for a long time 2 The material lost means property and datum lost 2 2 Icon Notes 2 3 Waring When there is something wrong or strange smel...

Page 5: ...hildren the packaging materials which could become a source of danger It is forbidden to climb onto the appliance or rest any object on it It is forbidden to touch the unit with hands directly as the external parts of the appliance can reach temperatures of more than 158 5 3 Functional description of remote controller TEMP MODE FAN ON OFF PM10 50 0 00 UNIVERSAL A C REMOTE ON OFF Press this key to ...

Page 6: ... 80 6 DB 66 2 DB 4 Above data is subject to our change without prior notification 3 2 Overall dimensions Unit Model PFP 100 V PFP 025 V PFP 040 V PFP 060 V PFP 080 V 35 43 27 56 A inch 43 31 51 18 59 06 B inch 14 41 22 28 30 16 38 03 45 91 fig 2 W Btu h gallon min psig W Btu h gallon min psig W Btu h gallon min psig 3 m h dB A W NPT inch inch inch lb lb PFP 025 V 2550 8700 0 97 1 54 1350 4600 1 01...

Page 7: ...coil only the width and palm vie for you leave more valuable space 3 Appearance fashion The appearance of the radian of noble fashion white colour elegant and easy no matter in any one place will indoor become beautiful scenery 4 Using a new design of vertical wind disk controller appearance vogue interface contracted operating more simple more human nature Fig 3 Water inlet cooling or heating Wat...

Page 8: ...troller HEAT COOL HIGH LOW MID M M About buttons ON OFF BUTTON Pressing this button would start up or shut down the unit Press this button and select the mode you want to set Cooling mode cooling indicator light keeps on green Heating mode heating indicator light keeps on red Automatic mode cooling indicator light and heating indicator light flashes in turn Ventilating mode cooling and heating ind...

Page 9: ...rk must be suitably sized minimum inside pipe diameter 0 63inch 4 Installation Fig 16 A B C Attention When discharging directly into the main drains it is advisable to make a siphon to prevent bad smells returning up the pipe towards the room The pipe towards the room The curve of the siphon must be lower than the condensation collection bowl If the condensation needs to be discharged into a conta...

Page 10: ...er should be 19 69inch higher Y type filter should be installed in the water inlet of the unit Air release valve should be arranged on top of the hydraulic lines to avoid air retention Waterway system should be conducted the pressure test separately and not together with the Vertical Water Fan Coil Water inlet Water outlet Water outlet with 3 way valve Water inlet with 3 way valve fig 10 fig 11 4 ...

Reviews: