Smart Load Connection
The ES-T inverter provides one isolated change over relay contact (4A - 250Vac max) which
allows activating secondary storage systems or domestic loads based on the state and energy
balance of the system.
See the connection instructions shown in the following figure:
RS485
RL4
NC NO CO
M
CAN BATT
CAN EXT
LAN
}
Load Control
RS485
RL4
NC NO
COM
CAN BA
TT
CAN EXT
LAN
COMMON
MAX 4A - 250V
NO (NORMALLY OPEN)
NC (NORMALLY CLOSED)
Fig. 25: Smart Load Connection
The relay contact can switch loads with absolute maximum ratings up to 4A - 250Vac. If you
intend to control loads with higher rated power, it is necessary to install an external switch and
use the ES-T contact to create the control circuit of the external switch.
To set the contact operating mode it is necessary to access the “SETTINGS” configuration
menu and set the “LD1 - SMART LOAD” parameters of the “HOME AUTOMATION” menu
according to the desired energy management needs. Refer to the SYSTEM PROGRAMMING
section.