61
en
SETTINGS
Smart LD
Battery Manager
HOME AUTOMATION
LD On/Off
LD - P SEL
P Start LD
P hyst LD
Timer LD
LD - Day
LD - Start Time
LD - Stop Time
Battery Manager Sel.
Batt. Disch - Start Time
Batt. Disch - Stop Time
Batt. Ch - Start Time
Fig. 40: Diagram of Settings Home Automation menu
“SMART LD”
The page allows to set the SMART LOAD operating mode for the load controlled by the isolated
changeover contact (4A - 250Vac max) available in the ES-T. Through the contact it is possible
to enable secondary storage systems and / or domestic loads based on the status and energy
balance of the system.
PARAMETER
VALUE
DESCRIPTION
LD On/Off
ON/OFF
LD program enable (Default = OFF)
LD – P sel
PV / GRID
Selection of the activating power type
P start LD
0 – 99999 W
Power on threshold setting
P hyst LD
0 – 99999 W
Hysteresis power off setting