11. Now let the shrink sleeve cool down for 10 ... 15 minutes.
12. Now proceed with the shrinking process on the cable.
– The shrinking process is complete when the shrink sleeve makes close contact
with the cover spigot, without folds, and the hotmelt adhesive comes out all round.
13. Let the cable pass-through element cool down for 30 minutes; do not disturb this
process.
14. Close any unused cover spigots with blank plugs VS 32 or VS 20 (not included in the
delivery package).
– Tightening torque 5 Nm (or 4 Nm respectively).
5.2
Connection to PV generator
DANGER!
Fatal electric shock hazard!
■
■
Make sure that the DC and AC supply cables are de-energized.