en
65
Display
Description
Device type
Inverter type
Serial No.
Inverter serial number
Firmware
Firmware version installed in the inverter
State
Current operating status
Warning
Current warning message
Commissioning
Date of initial start-up
Operating hours
Total operating hours in mains operation
MAC address
MAC address of the inverter
3. Press
to return to the Main Menu.
77
Displaying the operating status of the inverter
The status LED (Figure 41/No. 2) signals the current operating status of the inverter by its
different signal colors. The status message, which gives a more detailed description of
the operating status, is displayed at the graphics display.
In addition to the status messages, the inverter also displays warnings. Warnings result
from device errors or external failures. The inverter continues to feed power into the grid,
but it is possible that yield is reduced. Warnings are independent of the operating status
and are displayed on the graphics display alternately with the current status message.
Status LED
Operating status
Description
Off
-
Inverter is switched off
Flashes green
Booting
Inverter is starting up
Green
Mains operation
Mains feed-in (normal operation)
Flashes orange
-
Warning
→
no grid disconnection
Orange
Failure
External failure
→
grid disconnection
Red
Error
Device error
→
grid disconnection
Flashes red
Blocked
Inverter is blocked
→
grid disconnection
The "Fault", "Error", and "Blocked" operating status messages, as well as the warnings,
usually require certain measures to be carried out by the qualified electrician in charge
(see Section 8).