en
49
6�6
Displaying measured values
The current measured values of the inverter can be accessed in the “Measured values”
menu.
1. In the Main Menu, select the "Measured values" menu.
Figure 32 "Measured values" menu
2. Select a menu item:
Menu item
Description
System
Measured values
Power Unit 1
Measured values of MPP trackers 1 and 2
Power Unit 2
Measured values of MPP trackers 3 and 4
3. Press
or
to scroll through the measured values:
– Measured values under "System":
Measured value Description
Unit
Vac L1, Vac L2,
Vac L3
Phase voltage L1, L2 and L3
V
Iac L1, Iac L2,
Iac L3
Output current L1, L2 and L3
A
Pac
Output power
W
S
Apparent power
VA
Q
Reactive power (+: overexcited / −: underexcited)
var
cos
φ
Power factor (OEX: overexcited / UEX: underexcited)
-
Frequency
Mains frequency
Hz
– Measured values under "Power unit 1":
Measured value Description
Unit
Vdc 1, Vdc 2
Input voltage at MPP tracker 1 / MPP tracker 2
V
Idc1, Idc2
Input current at MPP tracker 1 / MPP tracker 2
A
Pdc
Input power (total of MPP trackers 1 and 2)
W
Temperature
Cooling element temperature (MPP trackers 1 and 2)
°C
Summary of Contents for SM30HT4