ATTENTION!
Non-observance of these safety instructions may result in material damage.
Note
Notes contain additional information or facilitate operation of the inverter.
2 Safety
2�1
Intended use
SolarMax HT series inverters are designed exclusively for the conversion of the direct cur-
rent generated by PV modules into alternating current which conforms to the parameters
of the public grid. Any other use is contrary to the intended use.
Inverters of the HT series may only be used in combination with PV modules which comply
with the IEC 61730 standard. Inverters of the HT series may only be connected to Class
II PV generators.
2�2
Safety instructions
DANGER!
Fatal electric shock hazard!
In daylight the PV generator supplies the inverter with a dangerously high DC
voltage.
■
■
Make sure that all electrical input conductors to the inverter are de-ener-
gized before starting any work on the inverter or the input conductors.
DANGER!
Fatal electric shock hazard!
Components within the inverter are charged with a high voltage.
■
■
Never open the inverter while it is in operation.
WARNING!
Risk of injury from electric arc!
Removing the DC connectors when live can lead to dangerous electric arcs.
■
■
Switch off the DC disconnector at the inverter before removing the DC
connectors.
Summary of Contents for SM30HT4
Page 1: ...Instruction manual SolarMax HT series 30HT4 32HT4...
Page 10: ...10 3 4 Dimensions mm 590 580 397 847 871 Figure 1 Dimensions with wall mounting bracket...
Page 11: ...en 11 3 5 Views of the unit 2 3 4 12 11 9 10 8 7 7 6 1 5 Figure 2 Views of the unit...
Page 74: ...SolarMax Service Center hotline solarmax com www solarmax com service 2014 05 en...