66
11 Technical data
SM30HT4
SM32HT4
Input parameters
MPP voltage range
1)
430 to 850 V
460 to 850 V
Minimum DC voltage
250 V
250 V
Maximum DC voltage
1 000 V
1 000 V
Maximum DC current
4 x 18 A
4 x 18 A
Number of MPP trackers
4
4
Number of string connections
4 x 2
4 x 2
Connection type
Wieland PST40i1 (identical to MC4)
Overvoltage category
2
Output parameters
Rated output power
30 000 W
32 000 W
Maximum apparent output
power
30 000 VA
32 000 VA
Maximum AC current
3 x 44 A
3 x 47 A
Nominal mains voltage / range
230 / 184 to 276 V
Nominal mains frequency / range
50 / 45 to 55 Hz
Power factor cos
φ
Adjustable from 0.8 overexcited to 0.8 under-
excited
Distortion factor at rated output
power
< 3 %
Connection type
Screw terminal
Grid connection
Three-phase (L1 / L2 / L3 / N / PE)
Overvoltage category
3
Protection class
I
Efficiency
Maximum efficiency
98 %
98 %
Europ. efficiency
97.5 %
97.5 %
Power input
Own consumption, night
0 VA
Environment
Protection class
IP65
Ambient temperature range (for
rated power output)
−20 to +60 °C (−20 to +45 °C)
Max. operating level above
sea level
2000 m
Relative humidity
0 to 98 % (without condensation)
Environmental category
In the open
Suitable for wet rooms
Yes
Level of pollution
3
Summary of Contents for SM30HT4
Page 1: ...Instruction manual SolarMax HT series 30HT4 32HT4...
Page 10: ...10 3 4 Dimensions mm 590 580 397 847 871 Figure 1 Dimensions with wall mounting bracket...
Page 11: ...en 11 3 5 Views of the unit 2 3 4 12 11 9 10 8 7 7 6 1 5 Figure 2 Views of the unit...
Page 74: ...SolarMax Service Center hotline solarmax com www solarmax com service 2014 05 en...