6�4�3 Setting the network parameters
The network parameters can be assigned in the "Settings" menu.
Note
Please take note of the information relating to MaxComm compatibility in Sec-
tion 11.3.
Device address
In order to communicate via an RS485 or Ethernet interface, the inverter needs a unique
device address on the network.
1. In the "Settings" menu, select the "Device address" parameter.
2. Set the parameter to the required value:
Parameter
Description
Device address
Address range: 1 to 249
Configuring the Ethernet interface
In addition to the device address, the following settings must be made to communicate
via Ethernet:
1. In the Main Menu select the "Network" menu.
2. In the "IP mode", select the required setting:
Setting
Description
DHCP client
The inverter is a DHCP client and is connected to a network with
DHCP server (factory setting).
Static
The inverter is connected to a network with static IP addresses.
3. If appropriate, configure the following parameters. These settings are only required in
"Static" IP mode (see step 2):
Parameter
Description (in brackets: factory settings)
IP
IP address (192.168.1.123)
Gateway
(192.168.1.1)
TCP port
(1234)
DNS1
Domain Name Server 1 (192.168.1.1)
DNS2
Domain Name Server 2 (192.168.1.1)
Netmask
Subnet mask (255.255.255.0)
4. Check whether the Ethernet connection indicator appears on the graphics display
(see Section 7.1).
Summary of Contents for SM30HT4
Page 1: ...Instruction manual SolarMax HT series 30HT4 32HT4...
Page 10: ...10 3 4 Dimensions mm 590 580 397 847 871 Figure 1 Dimensions with wall mounting bracket...
Page 11: ...en 11 3 5 Views of the unit 2 3 4 12 11 9 10 8 7 7 6 1 5 Figure 2 Views of the unit...
Page 74: ...SolarMax Service Center hotline solarmax com www solarmax com service 2014 05 en...