background image

 

 

 

 

M4 SS Nut 

Instructions:  

1.

 

Insert the flat washer into the screw and then insert the cup washer before you place it in the grounding 

holes. 

2.

 

Secure the screw to the aluminum frame using the toothed washer and a backing nut on the end of the 

screw as you place the grounding conductor. 

3.

 

Make a small loop with the grounding conductor and place it between the flat washer and the cup washer. 

Make  sure  that  the  copper  does  not  come  in  contact  with  anything  but  the  stainless  steel  to  avoid 

corrosion. 

4.

 

Use the backing nut to tighten the screw in place with a 4Nm torque and make sure that the toothed 

washer anchors the frame. 

 

Option 2: Bolt & nut Grounding 

Required material and composition structure: 

 

M4 SS cap bolt 

 

M4 SS Flat washer 

 

Grounding conductor 

 

M4 SS Cup washer 

 

M4 SS Toothed washer 

Instructions:  

1.

 

Place the cup washer with the concave side up between the frame and the wire. 

2.

 

Fix the wire between the flat washer and the cup washer 

3.

 

Insert the cap bolt to unify the washers with the frame. 

4.

 

Using the toothed nut tighten the bolt with the help of a wrench. Use a 1.5Nm torque to tighten the 

bolt. 

 

IMPORTANT! 

  A  professional  must  ground  the  system;  failure  to  comply with this  requirement  could  result  in 

serious damage, will reduce system performance and invalidate SOLARSOL’s Warranty for PV Modules. 

 

Summary of Contents for SSP27

Page 1: ...User Manual Photovoltaic Modules SSP27...

Page 2: ...User Manual Contents Module Size 4 Safety instructions 5 Installation guidelines 7 Mechanical installation 8 Electrical installation 10 Grounding 12 Maintenance and care 15 Transport and storage 15...

Page 3: ...l number of the product The label located on the back of the solar module contains important information about the Maximum Power Electric Tolerance Open Circuit Voltage Voc Short Circuit Current Isc M...

Page 4: ...module dimension SOLARSOL reserves the right to cancel the warranty of any of its products if the recommendations described in this manual are not followed Please keep this manual for future reference...

Page 5: ...systems can be installed on roofs or high ground however modules should be installed only on surfaces capable of supporting the additional weight of the panels The modules must be anchored to the ceil...

Page 6: ...UL 1703 only when it is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code Modules and module frames must not be drilled na...

Page 7: ...nted The installation structures can be located on roofs or even on the ground Install the photovoltaic modules avoiding shadow conditions produced by nearby bodies such as trees water tanks or antenn...

Page 8: ...method the photovoltaic modules must be insured in at least 4 different points Figure 2 Encircled in red the installation holes in the module s frame Modules can be installed in landscape or portrait...

Page 9: ...aluminum frame using the toothed washer and a backing nut on the end of the screw Normal level of load condition High level of load condition Screw fastening to assembly holes Applies to most of the e...

Page 10: ...e connector with IP67 Three By pass diodes are located at the interior of the Jbox for overcurrent protection Each module has two single conductor wires pre wired inside the junction box In addition t...

Page 11: ...onnect the modules in parallel make sure that each line contains the same number of photovoltaic modules Under normal conditions a photovoltaic module is likely to experience conditions that produce m...

Page 12: ...V module has two ground pre drilled holes with 4 mm diameter they are identified by the symbol and engraved at the center of both sides of the frame as seen on the following sketch Grounding Holes 4 m...

Page 13: ...us must connect to the grounding electrode It is convenient that the grounding bus and the PV circuit DC disconnect are in the same enclosure 9 The junction point between the grounding connector bus a...

Page 14: ...ith a 4Nm torque and make sure that the toothed washer anchors the frame Option 2 Bolt nut Grounding Required material and composition structure M4 SS cap bolt M4 SS Flat washer Grounding conductor M4...

Page 15: ...ll times Regularly inspect the photovoltaic modules If you find any of the following defects SOLARSOL recommends you to contact your installer Crack son the glass Surface Burns on the cells or the bac...

Page 16: ...subject to change or adjust without notice Possible errors are not ruled out SOLARSOL is a registered trademark of Producciones Solares de M xico S A de C V For any clarification Contact Us PRODUCCIO...

Reviews: