background image

 

 

 

Safety instructions. 

                                   

IMPORTANT 

 

Before  installing,  wiring  or  handling  the  photovoltaic  modules,  please  read  the 

instructions below.  

 

The wrong installation of photovoltaic devices can result in serious injuries. 

 

All installation work must obey the standards established by international, national and local regulations. 

Before installation, remove all metallic object and jewelry. 

Safety equipment must be worn at all time during the installation.  

For your safety use insulated tools and gloves.  

Do not allow unauthorized people access to the installation area. 

Photovoltaic  systems  can be  installed  on  roofs  or  high  ground,  however, modules  should  be  installed only  on 

surfaces capable of supporting the additional weight of the panels. 

The modules must be anchored to the ceilings by a formal structure result of a complete load analysis. 

Do not install photovoltaic modules near flammable substances, gases or vapors. 

The  fire  rating  of  this  module  is  valid  only  when  mounted  in  the  manner  specified  in  the 

mechanical mounting instructions.  

 

Work EXCLUSIVELY in dry conditions. For your safety, do not install or manipulate 

the 

photovoltaic modules under adverse weather conditions.  

 

Reflection  caused  by  snow  or  water  can  increase  sunlight,  raising  the  power 

generated by the solar modules. Additionally, low temperatures can boost the panel power. 

Summary of Contents for SSP27

Page 1: ...User Manual Photovoltaic Modules SSP27...

Page 2: ...User Manual Contents Module Size 4 Safety instructions 5 Installation guidelines 7 Mechanical installation 8 Electrical installation 10 Grounding 12 Maintenance and care 15 Transport and storage 15...

Page 3: ...l number of the product The label located on the back of the solar module contains important information about the Maximum Power Electric Tolerance Open Circuit Voltage Voc Short Circuit Current Isc M...

Page 4: ...module dimension SOLARSOL reserves the right to cancel the warranty of any of its products if the recommendations described in this manual are not followed Please keep this manual for future reference...

Page 5: ...systems can be installed on roofs or high ground however modules should be installed only on surfaces capable of supporting the additional weight of the panels The modules must be anchored to the ceil...

Page 6: ...UL 1703 only when it is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code Modules and module frames must not be drilled na...

Page 7: ...nted The installation structures can be located on roofs or even on the ground Install the photovoltaic modules avoiding shadow conditions produced by nearby bodies such as trees water tanks or antenn...

Page 8: ...method the photovoltaic modules must be insured in at least 4 different points Figure 2 Encircled in red the installation holes in the module s frame Modules can be installed in landscape or portrait...

Page 9: ...aluminum frame using the toothed washer and a backing nut on the end of the screw Normal level of load condition High level of load condition Screw fastening to assembly holes Applies to most of the e...

Page 10: ...e connector with IP67 Three By pass diodes are located at the interior of the Jbox for overcurrent protection Each module has two single conductor wires pre wired inside the junction box In addition t...

Page 11: ...onnect the modules in parallel make sure that each line contains the same number of photovoltaic modules Under normal conditions a photovoltaic module is likely to experience conditions that produce m...

Page 12: ...V module has two ground pre drilled holes with 4 mm diameter they are identified by the symbol and engraved at the center of both sides of the frame as seen on the following sketch Grounding Holes 4 m...

Page 13: ...us must connect to the grounding electrode It is convenient that the grounding bus and the PV circuit DC disconnect are in the same enclosure 9 The junction point between the grounding connector bus a...

Page 14: ...ith a 4Nm torque and make sure that the toothed washer anchors the frame Option 2 Bolt nut Grounding Required material and composition structure M4 SS cap bolt M4 SS Flat washer Grounding conductor M4...

Page 15: ...ll times Regularly inspect the photovoltaic modules If you find any of the following defects SOLARSOL recommends you to contact your installer Crack son the glass Surface Burns on the cells or the bac...

Page 16: ...subject to change or adjust without notice Possible errors are not ruled out SOLARSOL is a registered trademark of Producciones Solares de M xico S A de C V For any clarification Contact Us PRODUCCIO...