Mechanical installation.
The module is considered to be in compliance with UL 1703 only when the module is mounted in the manner
specified by the mounting instructions below.
SOLARSOL photovoltaic modules can be installed using the holes found in the aluminum frame (See Figure 2).
They can also be installed using a clamp system.
For any installation method, the photovoltaic modules must be insured in at least 4 different points.
Figure 2. Encircled in red, the installation holes in the module’s frame.
Modules can be installed in landscape or portrait orientation.
The Fire Class Rating of the module in a mounting system in combination with roof covering complete with the
requirements to archive a class C.
To maintain the Fire Class Rating C, the system should have a minimum 10 cm gap between the module frame
and the mounting surface and it must be installed ONLY on surfaces resistant to fire.