safety.  The  grounding  connections  between 
modules  must  be  approved  by  a  qualified 
electrician, the grounding itself must be made 
by  a  qualified  electrician.  Recommended 
torque  value  is  2.3N.m  (20in-lb).  The 
grounding  clip  accepts  solid  uninsulated 
copper  wire  sizes  10  or  12  AWG.  The  wire 
must not be nicked 

 

Figure 3 

 

Notice:  Use  TYCO.  1954381-1  (UL  Certificate 
No. E69905). 
The  module  shall  wire  in  accordance  with  the 
NEC,  the  grounding  method  of  the  frame  of 
arrays shall comply the NEC, article 250 

Operation and Maintenance 

No  routine  maintenance  is  required. 

However  it  is  advisable  to  perform  periodic 
inspection of the modules for damage to glass, 
backskin, 

or 

frame. 

Check 

electrical 

connections  for  loose  connections  and 
corrosion.   

PV  modules  can  operate  effectively  without 
ever  being  washed,  although  removal  of  dirt 
from  the  front  glass  can  increase  output.  The 
glass  can  be  washed  with  a  wet  sponge  or 
cloth.  Wear  rubber  gloves  for  electrical 
insulation. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 