22
Errors and changes excepted. | © 2022 SOLARWATT GmbH
5. Mounting with 4 clamps (short side)
6. Mounting with an insertion system (long side)
areas approved for fastening the center of the clamp
260
260
260
260
Max. permitted pressure load up to: 1,600 Pa (test load 2,400 Pa)
Max. permitted suction load up to: 1,067 Pa (test load 1,600 Pa)
Max. permitted pressure load up to: 3,600 Pa (test load 5,400 Pa)
Max. permitted suction load up to: 1,600 Pa (test load 2,400 Pa)
7. Mounting with an insertion system (short side)
8. Mounting with an insertion system (short side)
areas approved for fastening the center of the clamp
850
50
50
Max. permitted pressure load up to: 1,600 Pa (test load 2,400 Pa)
Max. permitted suction load up to: 1,067 Pa (test load 1,600 Pa)
Max. permitted pressure load up to: 3,600 Pa (test load 5,400 Pa)
Max. permitted suction load up to: 1,600 Pa (test load 2,400 Pa)
NOTE
The solar modules can
be installed both
vertically (portrait)
and horizontally (landscape).
horizontal installation
(landscape)
vertical installation
(portrait)
#04038 | Rev 2 | 20.06.2022