5. Mounting with 4 clamps (short side)
areas approved for fastening the center of the clamp
280
280
280
280
Max. permitted pressure load up to: 1,600 Pa (test load 2,400 Pa)
Max. permitted suction load up to: 1,067 Pa (test load 1,600 Pa)
NOTE
The solar modules can
be installed both
vertically (portrait)
and horizontally (landscape).
horizontal installation
(landscape)
vertical installation
(portrait)
NOTE
It is not permitted to use SOLARWATT Panel vision solar modules as overhead
glazing. For roof installation, these solar modules must be installed over a
fire-resistant roof covering („hard roofing“).
NOTE
Under mechanical load, no contact between solar glass and hard materials (eg.
metal, glass) may occur. The drainage holes in the module frame must not be
covered, as it could cause frost damage on the module frame. Do not place any
plug connectors in the frame.
NOTE
When used with flat roof systems, the same clamping areas and permitted
loads are valid as for mounting variants 3 and 4. Please ensure that the
mounting systems are suitable for the specific purpose.
#04038 | Rev 2 | 20.06.2022