Comply  with  the  minimum  distance  of  5  mm 

between the solar modules to allow the materi

-

al to expand without tension.
For system documentation, note the positions 

of the modules and their serial numbers. Before 
commissioning, a final inspection of the entire 

system is recommended.

The solar module is a glass product and should be handled with appropriate care. Do 
not stand on the solar module. Do not allow any objects to fall or place any objects on 

the solar module. Never hold or transport the solar module by the junction box or con

-

nection cables. For installation SOLARWATT strongly recommends the usage of clean, 
fat and silicone oil free gloves!

WARNING

The solar modules are not designed for concentrated irradiation. Bundling or concen-

trating solar irradiation through lenses or mirrors is therefore not permitted and can 
damage the solar modules.

WARNING

SOLARWATT  solar  modules  fulfill  all  the  re-
quirements  of  the  extended  test  standard  IEC 
61215,  including  the  increased  pressure  load, 

making them ideal for use in areas with large 
amounts of snow. The local regulations or the 

standard EUROCODE 1 (EN 1991-1) should be 

used for the calculation of the snow loads on 
the module. It is important to note that these 
standards are designed for impact on structures 
and do not explicitly take into account the ins

-

tallation of solar modules.  

The  solar  module  heats  up  during  operation.  Ensure  that  there  is  sufficient  rear  venti-
lation to avoid reductions in yield. Also ensure that no flammable gases can escape or 

accumulate close by.

NOTE

In regions with particularly high snowfall, the 
pressure load calculated in accordance with 
the standard based on local snow load infor

-

mation may be significantly exceeded due to 
snow  overhang  or  build-up  on  the  solar  mo-

dules. 
SOLARWATT therefore tests its modules abo

-

ve and beyond the standard IEC 61215 and in 

accordance with additional standards, taking 
into account additional loads in the event of 

snow overhang or build-up to reflect the actu-

al loads encountered in practice and to ensure 

that our products work safely throughout their 
entire service life. 

• 

Please take care when handling and in

-

stalling  glass-glass  modules.  The  edges 

and especially the corners are sensitive 
to impact even though they are made of 

high-quality hardened glass.

• 

Make  sure  that  the  plug-in  connections 
are  not  located  on  a  water-channeling 

surface

PAGE 4 | SUBJECT TO CHANGE | © 2019 SOLARWATT GMBH | AZ-TM-PMS-1703 | REV 006 | STATUS: 08/2019

Summary of Contents for VISION 36M GLASS

Page 1: ...tion EN 62446 Grid coupled photovoltaic systems IEC 60364 Erection of low voltage systems VDE DIRECTIVES VDE 0100 Erection of low voltage systems VDE 0105 100 Operation of electrical systems EXCLUSION...

Page 2: ...rements please contact the responsible local authorities and the network operator SOLARWATT solar modules are made from high quality materials and high performance solar cells and are therefore extrem...

Page 3: ...ixed to suitable substructures which are designed for the relevant mechanical wind and snow loads as well as the weight of the solar modules The instructions from the installation system manu facturer...

Page 4: ...for the calculation of the snow loads on the module It is important to note that these standards are designed for impact on structures and do not explicitly take into account the ins tallation of sol...

Page 5: ...ctor of 1 5 in accordance with the IEC 61215 standard and apply to flat and sloping roofs with unobstructed snow slipping The maximum given load is valid only for on roof application Fixing by long si...

Page 6: ...pplication class can be used in systems with unrestricted access the relevant regulations must be complied with SOLARWATT solar modules qualified within this application class in accordance with IEC 6...

Page 7: ...ay also be used in the recommended dose Do not use aggressive cleaning agents or metal objects as they can be particularly dama ging to the hardened glass surface The electric cables should where acce...

Page 8: ...ite the high quality of our products please contact your dealer directly or SOLARWATT GmbH Maria Reiche Str 2a 01109 Dresden Germany Tel 49 351 8895 0 Fax 49 351 8895 100 info solarwatt com Certified...

Reviews: