Example UL [USA]: 

The modules can be connected to the grounding holes using 

a lay-in lug and a bolt with serrated washer, washer, and nut 

(see image: “Correct connection of grounding wire“). 

1

2

3
4

5

1  Nut

2  Serrated washer

3  Washer 

4  Bolt

5  Lay-in lug

Image 4: Ground connection using a cable lug, a bolt, a serrated washer, 

washer, and nut.

We recommend using the components listed blow. 

Any UL approved PV grounding method and components are 

also acceptable in the US and Canada.

Table: Recommended components

Item

Description Manufacturer 

/ Distributor

Manufacturer 

/ Part number

Grounding lug

Lay-in lug

Ilsco

GBL-4

Bolt

#6-32, SS

McMaster Carr

92314A148

Serrated washer 

M5, SS

McMaster Carr

91120A140

Washer

ID 9/64“, OD 

3/8“, SS

McMaster Carr

92141A007

Nut

#6-32, SS

McMaster Carr

91841A007

See www.ilsco.com; www.mcmaster.com

WARNING!

Warns of explosion risk from batteries 

 

▹ If modules are used to load batteries, the battery is to be 

installed in such a manner that the performance of the 

system and its users are not endangered.

 

▹ The recommendations and regulations of the battery 

manufacturer concerning installation, operation, venti-

lation, and maintenance must be adhered to.

 

▹ Batteries should be kept away from persons and ani-

mals and protected from sunlight, rain, snow, or falling 

objects.

 

▹ When loading most batteries generate gaseous 

hydro-gen which can also explode. To prevent this from 

happening sufficient ventilation must be provided and 

open flames and sparking must be avoided. For outdoor 

installations the batteries should be kept in a ventilated 

container provided especially for this purpose.

Maintenance 

SolarWorld recommends inspecting the system in regu-

lar intervals: All PV modules should be inspected yearly for 

safe electrical connections, corrosion and intact mechanical 

connections. Loose connec-tions can damage the module or 

the module series. During this inspection it should also be 

ensured that the wiring is in good condition. Given a sufficient 

tilt (over 15°) it is usually not necessary to clean the modules 

(rainfall will have a self-cleaning effect). Modules that are 

installed horizontally (0 – 15° tilt angle) must be cleaned more 

often because a sufficient self-cleaning from rainfall, as with 

stronger tilted modules, is not given.
 

In case of heavy soiling we recommend cleaning the modules 

using lots of water (from a hose) without any cleaning agents 

and using a gentle cleaning implement (a sponge). Dried dirt 

must never be scraped or rubbed away, as this may cause mic-

ro-scratches. Any problems that may arise should be solved by 

an authorized specialist. Please also observe the maintenance 

information of all components used, such as support frames, 

charging regulators, inverters, batteries etc.

Disclaimer of liability  

SolarWorld accepts no liability for the use and functionality 

of the modules in case of non compliance with this User 

Information. Since compliance with this guide and the 

conditions and methods of installation, operation, use and 

maintenance of the modules are not checked or monitored 

by SolarWorld AG, SolarWorld AG accepts no liability for 

damage arising through improper use or incorrect installation, 

operation, use or maintenance. 

SolarWorld AG

Martin-Luther-King-Str. 24

53175 Bonn

Germany

Telefon: 

+49 - 228 - 55920 - 0

Telefax: 

+49 - 228 - 55920 - 99

service@solarworld.de

www.solarworld.de

SolarWorld Ibérica, S.L.

C/La Granja 15, Bloque B-1°B

28108 Alcobendas, Madrid

Spain

Tel.: +34 - 91 - 4905999

Fax: +34 - 91 - 6574967

service@solarworld.es

www.solarworld.es

SolarWorld California Inc.

4650 Adohr Lane

Camarillo, CA 93012

USA

Tel.: +1 - 800 - 947 - 6527

Fax: +1 - 805 - 388 - 6395

service@solarworld-usa.com

www.solarworld-usa.com

SolarWorld France

Hôtel de l’Entreprise,  

Bouchayer-Viallet

31, rue Gustave Eiffel

38000 Grenoble

France

Tel + 33 (0) 43 821 00 50

Fax +33 (0)4 38 21 00 59

service@solarworld.fr

http://www.solarworld.fr

SolarWorld Africa Pty. Ltd.

20

th

 Floor

1 Thibault Square

Cape Town, 8001

South Africa

Tel.: +27 - 21 - 421 - 8001

Fax: +27 - 21 - 421 - 8002

service@solarworld-africa.co.za

www.solarworld-africa.co.za

SolarWorld Asia Pacific Pte. Ltd.

72 Bendemeer Road

#07-01, Luzerne

Singapore 339941

Singapore

Tel.: +65 - 6842 - 3886

Fax: +65 - 6842 - 3887

service@solarworld.sg

www.solarworld.sg

Reviews: