Control Keypad
________________________________________________________________________________________
7.6.2
Display Mode
±
page 0
% OF MOTOR FLA
XX%
Displays in MINIMIZED MODE and MAXIMIZED MODE
(Refer to section
7.6.3 page 32)
Display and default
values
Range
Description
% OF MOTOR FLA
I<0.1 FLC
Displays operating current as a percentage of motor FLA (Full
Load Ampere).
6WDUWHU¶V'HIDXOW'LVSOD\$IWHUSUHVVLQJ
Mode
or
Select
keys, a
time delay is initiated. Following the delay, the LCD returns to
GLVSOD\³2)02725)/$´
AMP. VOLT
0 0
Displays Motors current and mains voltage.
OPTION CARD
Not Installed
NOT
INSTALLED/
INSTALLED
Displays whether option cards are installed in the RVS-DXM.
POWER
30kw
When power metering option is installed, displays active POWER
drawn by the motor.
Note:
Reading available in RVS-DXM58A and up.
POWER FACTOR
0.9
When power metering option is installed, displays POWER
FACTOR of motors power.
Note:
Reading available in RVS-DXM58A and up.
Note:
In this page parameters cannot be programmed.