6. Tile roof installation 
 
The assembly of solar collectors on a tile roof is done in a manner similar to that 
described above, with a different position of the vertical legs A3 that have to be 
placed horizontally underneath the E1/E2 in a parallel manner. The crosspieces X1 
or X2 and X3 shorts are not needed for tile roof installation. 
 
The profiles D3 longitudinal and transverse E1 or E2 have to be fixed to the roof with 
strength and without compromising its tightness. The fixing procedure will depend on 
the characteristics of the roof. With the installation fittings are supplied some 
perforated flexible metal strips to facilitate this fixation on certain roof configurations. 
(See fig. 19) The collectors and the support system can withstand wind velocity up to 
120km/h and weight of snow up to 80cmheight at 45 degrees. 
 

 

 

Figure 19. 

 
 
 
 
7. Connections and Hydraulic Circuit 
 
The collectors or different groups of solar collectors must be connected hydraulically 
to form a closed primary solar collection circuit. The use of copper pipes is 
recommended, with a wall minimum thickness of 1 mm and an adequate diameter for 
the circulation flow of each part.  
 
The entry of liquid to the group of solar collectors will be from the end at the bottom 
of the collector. On the top end connection a plug must be installed. The output of 

Summary of Contents for 1,75

Page 1: ...SOLE S A Solar Collectors Installation Manual GB SOLAR COLLECTORS INSTALLATION MANUAL MODELS 1 75 2 00 2 50 2 70...

Page 2: ...allation 11 5 1 Installation of longitudinal profiles D3 and Z angle E1 E2 11 5 2 Installation of vertical legs A3 and the long cross pieces X1 1 X2 13 5 3 Installation of vertical legs A3 and the lon...

Page 3: ...before starting the installation that he has all the necessary parts and all the security measures have been taken in order to carry out the installation safely The installer must use protective glove...

Page 4: ...Side 20 mm glass wool back 40 mm rock wool Casing Aluminium profile epoxy powder oven painted Free of bolts and rivets Sea Water resistant Glass Tempered low iron prismatic glass 4 mm Sealing EPDM Ru...

Page 5: ...antaneous energy efficiency curve of solar collector Figure 2 Efficiency curve of Selective Collector 2 2 Support Frame There are two sets of support frames for a single collector EST1 or for two coll...

Page 6: ...4 Figure 3 Support frame components EST1 for a single solar collector Figure 4 Support frame components EST2 for two solar collectors The support frames allow the installation of the solar collectors...

Page 7: ...uld be carried out respecting the instructions of the person in charge of the project who should have taken into consideration the effect of the orientation inclination and possible shadows in the cal...

Page 8: ...thickness and size of the bench should be sufficient to ensure stability of the whole in case of strong gusts of wind In any case the solution adopted should ensure the solidity and stability of the s...

Page 9: ...A B 1 75 1000 mm 895 mm 2 00 970 mm 895 mm 2 50 1175 mm 895 mm 2 70 1248 mm 895 mm Figure 8 Bank of Two Solar Collectors TYPE A B C D 1 75 2060 mm 895 mm 582 5 mm 1000 mm 2 00 2000 mm 895 mm 552 5 mm...

Page 10: ...895 mm 552 5 mm 970 mm 650 mm 895 mm 2 50 3645 mm 1440 mm 485 mm 1175 mm 685 mm 895 mm 2 70 3864 mm 1440 mm 558 mm 1248 mm 794 5 mm 895 mm Figure 10 Bank of Four Solar Collectors TYPE A B C D E 1 75 4...

Page 11: ...439 mm 582 5 mm 970 mm 650 mm 895 mm 2 50 6115 mm 1440 mm 485 mm 1175 mm 685 mm 895 mm 2 70 6480 mm 1440 mm 558 mm 1248 mm 794 5 mm 895 mm Figure 12 Bank of Six Solar Collectors TYPE A B C D E 1 75 63...

Page 12: ...allation of the longitudinal profiles D3 and the Z angles E1 E2 Place the two longitudinal profiles D3 on the floor at the indicated distance so that both profiles U remain outward oriented Place the...

Page 13: ...SOLE S A Solar Collectors Installation Manual 12...

Page 14: ...link them into contact with each other through a bolt M10x20 with nut and washer without tighten it yet Place the two vertical legs A3 parallel on the floor so that both U profiles are oriented toward...

Page 15: ...oles depending on the inclination that wants to be given to the collectors Both profiles should be horizontal Screw with the two bolts M10x16 in each profile with its respective nuts Join the structur...

Page 16: ...re match those holes back of the collectors Adjust the position of the collectors if necessary Adjust the higher cross E1 or E2 profile to the collectors and tighten the bolts that bind to the longitu...

Page 17: ...roof With the installation fittings are supplied some perforated flexible metal strips to facilitate this fixation on certain roof configurations See fig 19 The collectors and the support system can...

Page 18: ...s of solar collectors with each other and or pipes of hydraulic circuit must be made so as to ensure that expansion does not cause excessive pressure tensions on the connections or on the collectors f...

Page 19: ...atures higher than 120 C without deteriorat ion The circulating fluid must contain a sufficient amount of antifreeze liquid to avoid any risk of freezing The freezing temperature of the fluid circuit...

Page 20: ...is to verify that the connections between solar collectors have no leaks If that is so the fittings should be tightened using two keys so as to avoid transmitting force tortion to the pipes of the ab...

Page 21: ...tightness in the closed circuit connections and the entry and exit of each collector and the connections between them Fix if necessary or replace items parts in poor condition The support of solar col...

Page 22: ...shed July 2008 Version 3 SOLE S A SOLAR DOMESTIC APPLIANCES MANUFACTURER Lefktron Laikon Agonon 136 71 Acharnai Athens Greece Tel 30210 2389500 Fax 30210 2389502 Email export sole gr www eurostar sola...

Reviews: