Installation 

9

99

Connections 

There are 

two

 connections that must be made to operate your converter. Be certain that your low-

voltage input harness is connected to your 12V system. Make the 2-pin Anderson SB-50 

low voltage 

output system connection to your low-voltage input harness

, as shown in 

photos one and two. 

Low Voltage Output: Anderson Connector 

Photo One

 

 

 

 

Photo Two

 

To bring 

high voltage input

 power to your unit you must connect the three-pin, two-wire high-

voltage input Deutsch connector to your 

high-voltage output harness

, as shown in photos three and 

four.  

Photo Three

 

 

Photo Four

 

 

High-Voltage Input: Deutsch Connector 

 

Operation of your converter begins as soon as the unit is connected to a power source. 

If your unit is not operating after having been linked to a power source, 

carefully

 check for possible 

loose connections. If you are still experiencing difficulties in getting your unit to begin operation, call 
the Solectria Customer Service Department at the number provided in your warranty. 

 

Reminder 

Always use connector 
grease for all Anderson 
SB-50. 

Summary of Contents for DC-DC 750

Page 1: ...Solectria DC DC 750 Converters Owner s Manual First Edition Solectria Corporation 33 Industrial Way Wilmington Massachusetts 01887 ...

Page 2: ...t at the phone number provided in your warranty Please be prepared to provide the following information Your name Name and edition of your manual Page number s where the error s appear Serial number of your unit Please feel free to call with any suggestions that you may have regarding the content of your manual 2000 Solectria Corporation All Rights Reserved No part of this manual may be reproduced...

Page 3: ...______________________ 1 Applications and Features _________________________________________________________ 1 Available and Custom Options______________________________________________________ 1 Specifications ____________________________________________________________________ 1 Dimensions ______________________________________________________________________ 6 Installation _____________________...

Page 4: ...t you will find the following symbols Hearing Protection Required Eye Protection Required Risk of Electrical Shock Risk of Burns from Battery Acids Always follow any safety instructions that are given at the beginning of a procedure If you are uncertain as to the safe and proper handling of your unit contact the Solectria Customer Service Department WARNING Indicates the serious risk of personal i...

Page 5: ...V 2 0 0 4 0 0 V 1 3 2 V 2 0 0 4 0 0 V 2 4 V 4 4 4 4 Anderson 12V gray 24V blue Deutsch DC DC750 Converters 12V and 24V Drawing is shown without the looms that protect the wires A B 14awg white 14awg green yellow INPUT OUTPUT Fuseholder 8awg white 8awg black ...

Page 6: ...r current Low idle power use Over output voltage shutdown This unit is not to be used to charge batteries See the DCDC750BC data sheets for information on units designed to operate with 12 24V batteries Also this unit is not designed to be used in parallel with 2nd or 3rd units on same circuit If more than 750W is needed use separate circuits with one DCDC750 on each circuit Interface package incl...

Page 7: ...D C D C 7 5 0 1 5 0 2 5 0 V 1 3 2 V 2 0 0 V 4 0 0 V 1 2 V 2 0 0 4 0 0 V 1 3 2 V 2 0 0 4 0 0 V 2 4 V Specifications 6 6 6 6 Dimensions ...

Page 8: ... pressure sprayer Large amounts of water will cause a malfunction If you have reason to believe water has entered the unit Do Not open the case Disconnect your unit and return it for service as soon as possible Units with extensive water damage may not be repairable Units returned to Solectria with the factory seal broken will be ineligible for warranty service Cooling Air Requirements Ample airfl...

Page 9: ...ns for 15 minutes Exhaust air temperature measured at the cooling fins should not exceed 65 C during this period The unit should not be routinely exposed to ambient temperatures above 65 C unless equipped with high power cooling fans designed for warmer climates Once you have decided upon a location for your unit you can now mount it into position using the unit s flanges industrial tape or Velcro...

Page 10: ... high voltage input power to your unit you must connect the three pin two wire high voltage input Deutsch connector to your high voltage output harness as shown in photos three and four Photo Three Photo Four High Voltage Input Deutsch Connector Operation of your converter begins as soon as the unit is connected to a power source If your unit is not operating after having been linked to a power so...

Page 11: ...packaging or use of incorrect lubricants Damage or corrosion caused by exposure to after market products the environment or chemical treatments and Wear items including but not limited to extension cords plugs connectors cables and enclosures In the event that it becomes necessary to return a product to us for service call ahead for a Return of Merchandise Authorization Number to help expedite the...

Page 12: ...eturn address and contact model number serial number date of purchase or receipt of purchase and reason for return If this information is not provided the repair will be delayed Customer will be charged an evaluation fee for Non Warranty items returned to Solectria Warranty items returned to Solectria that are operable will incur an evaluation fee Please call Solectria s Customer Service Departmen...

Reviews: