Installation and Operation Manual (Rev B)
40
2 Alarm
NoError
EepromErr
Protect0010
…
No
Yes
Figure 9.3 Present fault information
History Menu
This menu displays inverter data history, some of which may be modified with the keypad. Use
the
and buttons to scroll up and down through the list.
Pressing
will take the screen
back to the start menu. The following information can be found in the menu:
1.
Up to 100 entries of most recent fault messages are recorded and retrieved
2.
The latest 21 days operation history data is available
3.
Product software/hardware and serial number information
4.
Cumulative generated power information
3 History
1 ErrHist
2 Recent Data
3 Version
→
4 Etot
NoError
1.St2010.12.15 20:50
SPI CommError
2.Ed2010.12.15 20:59
IntProtect1
…
No
Yes
Enter day offset
←
2
→
ß
—
12/15
RunT - -h
Energy - -KW
Pmax - -KWh
IEEE1547
SN 11481220003
DSPVer. 0.01
LCDVer. 0.01
Etot
(
KWh
)
Figure 9.4.1 History Menu and Submenu (14TL)