1 Introduction
The PVI 3000, PVI 4000, PVI 5000 and PVI 5300 are residential/commercial single phase, grid-tied PV
inverters designed to be inter-connected to the electric utility grid. With this manual the PVI 3000 - PVI
5300 can be installed and operated safely. This installation guide is used as reference for commissioning
and as a guideline on how to use the inverter most effectively.
Feeding power into the grid involves conversion of the DC-voltage from the PV-array to grid compatible
AC-voltage by “inverting” DC to AC. This unit feeds power into a standard 240 VAC split phase
electrical system or two legs (phase to phase) of a 208 VAC, 3-phase commercial, industrial or
institutional facility’s electrical system that is connected to the electric utility grid.
If the PV system and inverter are providing the same amount of electrical power that the facility is using
then no power is taken from or fed into the utility grid. If the facility is using more power than the PV
system is providing, then the utility grid provides the balance of power. If the facility is using less power
than the PV system is generating, then the excess is fed into the utility grid.
Be sure to look into local regulations regarding net metering/inter-connection in your local area. Note
that some utilities need to change their revenue kWh meter for proper net metering measurement or
incentives/billing.
Fig. 1.1 Grid tied inverter application
The string PV concept
The use of string PV concept significantly reduces the cabling costs on a photovoltaic system. The use of strings of several PV
modules in series and one, two, three (or in some cases four) parallel strings of PV modules has proven advantageous by
delivering a high operating voltage to the solar inverter. This advantage is primarily reflected in a higher efficiency of the
inverter. Careful optimization of the overall inverter system’s cost and efficiency lead to the choice of a 600V DC maximum
system voltage for the power levels of the PVI 3000, 4000, 5000 and 5300 for use with 1kW to 7kW PV arrays per inverter.
Photovoltaic
Array
PVI 3000-5300
Inverter
Electric Utility
Grid