6.3 LCD Display Messages
The PVI 3000S-5300 inverter is supplied ready to operate so there are no settings that need to be
made by the user for fully automatic operation. The device comes standard with an LCD display
on which various data can be read. All indicated data is only an indication and has tolerances of
up to
±
5%.
The PVI 3000S-5300 inverter has a 16 x 2 LCD to show the operating status, input/output data,
and error messages. As long as the DC input voltage is above the pre-set threshold value of 200V,
the LCD continues to display the information following the process flow illustrated in the Figure
6.3.1.
The process flow may follow the
operating mode
,
fault mode
, or
idle mode
. The operating mode
is when the system goes from power-on to
system check
,
monitoring
, and then
grid feeding
mode
without any fault condition detected. The inverter should work following the operating
mode and eventually feeds the power to the grid. During the system check and monitoring
mode, if a fault condition that could be cleared automatically is detected, then the system will go
into the fault mode that the system could return to the operating mode once the fault condition
goes away. One obvious example is that an “island” condition is detected due to the grid going off
and then back on later, the fault condition is cleared when the power returns. If a fault cannot
clear on its own, then the system will enter the idle mode and will need a service person to clear
the fault and reset the system.
The following figures explain how the display works in the
operating mode
.
When the DC input voltage goes above the pre-set threshold value, the inverter is powered up
and will show the company name and model name (PVI 4000S in this example) on the LCD as
shown below.
After 3 seconds, software versions of two embedded CPU’s, Sequential and Current controllers,
will be displayed on the LCD. Afterward, the serial number (S/N), the baud rate (BR) / address
(ID) for the communication port will be displayed.
3 seconds ↓
S
E
Q
V
e
r
s
i
o
n
X
.
X
X
C
U
R
V
e
r
s
i
o
n
X
.
X
X
S
O
L
E
C
T
R
I
A
P
V
I
4
0
0
0
S