Installation
and
Operation
Manual
(REV
H)
PVI
6500
/
PVI
7500
30
Fig
2.5.2.2
PV
‐
String
connections
and
AC
connections
2.5.3
Wiring
inverters
in
parallel
PVI
6500
‐
7500
inverters
can
be
connected
in
parallel
when
more
power
is
needed.
In
the
parallel
configuration,
each
inverter
shall
connect
to
its
own
PV
array.
Do
not
connect
one
PV
array
to
more
than
one
inverter.
This
may
cause
the
inverter
to
work
abnormally.
The
Figure
2.5.3.1
on
the
following
page
shows
the
connections
between
inverters
and
PV
arrays
in
parallel
configuration.
It
is
recommended
balancing
practice
to
alternate
phase
connections
when
connecting
more
than
two
inverters
to
the
same
three
phase
service.