Installation
and
Operation
Manual
(REV
H)
PVI
6500
/
PVI
7500
51
GFDI
HW
Error
GFDI
detect
hardware
failure
‐
Turn
off the
inverter
and
restart.
‐
If
the
error
re
‐
occurs
Contact
installing
company
or
Solectria
Renewables
IpvH
Over
current
on
the
DC
side
‐
Use
a
suitable
meter
for
measuring
the
current
from
the
array.
‐
Verify
the
current
is
within
the
limits
for
the
inverter.
‐
Contact
the
installing
company
to
check
the
array
Driver
Fault
Driver
circuit
or
power
device
failed
‐
Turn
off the
inverter
and
restart.
‐
If
the
error
re
‐
occurs
Contact
installing
company
or
Solectria
Renewables
CalDataError
Calibration
data
is
out
of
range
‐
Turn
off the
inverter
and
restart.
‐
If
the
error
re
‐
occurs
Contact
installing
company
or
Solectria
Renewables
CalDataLoss
Calibration
data
is
lost.
‐
Turn
off the
inverter
and
restart.
‐
If
the
error
re
‐
occurs
Contact
installing
company
or
Solectria
Renewables
Ibuck
Over
Internal
converter
over
current
‐
Turn
off the
inverter
and
restart.
‐
If
the
error
re
‐
occurs
Contact
installing
company
or
Solectria
Renewables
Converter
Error
DC/DC
hardware
failed.
‐
Turn
off the
inverter
and
restart.
‐
If
the
error
re
‐
occurs
Contact
installing
company
or
Solectria
Renewables
ModuleTempMax
Module
temperature
high
‐
String
sizing
design
provides
too
low
DC
voltage
at
high
module
temperature
5.3
Maintenance:
Replacing
the
GFDI
Fuse
Before
replacing
the
fuse,
you
must
switch
off
the
DC/AC
disconnect
switch
and
AC
breaker
and
wait
for
at
least
5
minutes
for
system
to
discharge.
Verify
the
absence
of
voltage
with
a
voltmeter.
Remove
the
cover
of
the
inverter
wiring
box
and
remove
the
GFDI
fuse
holder
by
pulling
the
holder
towards
you
and
then
replace
the
GFDI
fuse
with
the
same
type
and
rating
(600VDC,
1A).
Fig
5.3.1
Replacement
of
the
GFDI
fuse
holder
1.
Turn
OFF
all
DC/AC
disconnect
switches and
AC
breaker
2.
Wait
for
at
least
5
minutes
3.
Exchange
the
GFDI
fuse
4.
Turn
ON
all
DC/AC
disconnect
switches
and
AC
breaker