Installation
and
Operation
Manual
(REV
H)
PVI
6500
/
PVI
7500
53
!
WARNING!
PV
arrays
are
always
energized
when
exposed
to
light
therefore
hazardous
voltage
is
still
present
on
the
terminal
blocks
and
the
PV
string
fuse
holders
even
when
the
DC/AC
disconnect
switch
is
switched
OFF.
Please
cover
the
PV
arrays
with
opaque
materials
during
PV
string
fuse
replacement.
CAUTION!
The
string
fuse
size
must
not
be
greater
than
the
maximum
fuse
size
rating
of
the
PV
module
provided
on
the
PV
module
manufacturer
data
sheet.
If
no
maximum
fuse
size
is
indicated,
please
contact
the
PV
module
manufacturer.
5.4
Factory
Service
Please
contact
Solectria
Renewables
customer
service
hotline
for
our
documentation
on
removing
and
replacing
the
top
inverter
section
(while
leaving
wiring
box
in
place).
5.5
Inverter
Replacement
Once
the
product
is
diagnosed
and
Solectria
determines
that
it
requires
Factory
Service,
the
product
can
be
removed
and
sent
back
using
the
original
shipping
box
and
packing
materials.
A
copy
of
the
RMA
number
must
be
included
in
the
package.
Documentation:
There
is
some
documentation
that
must
be
provided
with
the
returned
product.
Please
include
as
much
detail
as
possible.
1.
Serial
number
and
part
number
of
the
inverter
2.
Brief
description
of
system
it
has
been
used
in
and
failure
circumstances
(string
sizing,
events
prior
to
failure)
3.
Fault
message
on
LCD
display
or
fault
condition
that
occurred
4.
Can
the
failure
be
reproduced?
How?
The
following
sections
will
describe
the
steps
to
remove
and
subsequent
reinstall
the
inverter
with
the
wiring
box
remaining
on
the
wall.
5.5.1
Remove
the
Inverter
The
PVI
6500/7500
inverter
is
designed
to
be
easily
separated
from
the
wiring
box
and
removed
from
the
mounting
bracket.
You
must
wait
for
at
least
five
(5)
minutes
for
system
to
discharge
after
DC/AC
disconnect
switch
and
breakers
are
switched
OFF
and
locked
out
before
opening
the
front
cover
of
the
inverter
to
disconnect
the
wires.
Verify
the
absence
of
voltage
with
a
voltmeter.
Both
DC
and
AC
wires
that
are
disconnected
from
the
inverter
must
be
properly
terminated
with
insulating
means.
After
the
inverter
is
removed
from
the
mounting
bracket,
the
holes
that
the
wires
on
top
of
the
wiring
box
go
through
must
be
covered
with
the
cover
plate
that
is
attached
at
the
back
of
the
wiring
box
to
prevent
the
box
from
water
intrusion,
as
shown
in
the
figure
5.5.1.7.
WARNING!
PV
arrays
will
be
energized
when
exposed
to
light.
Cover
the
arrays
with
opaque
material
during
installation
and
wiring.
Verify
the
absence
of
voltage
with
a
DC
voltmeter.
WARNING!
Reconfirm
that
the
circuit
breaker
to
the
main
utility
is
switched
OFF
and
locked
out
before
disconnecting
the
power
cable
from
the
breaker
to
the
AC
terminal
block.
Verify
the
absence
of
voltage
with
an
AC
voltmeter.