Installation
and
Operation
Manual
(REV
H)
PVI
6500
/
PVI
7500
67
Inverter
Specifications
Name
‐
Part
number
PVI
6500
PVI
7500
Grid
output
(AC)
Grid
voltage,
nominal
(VAC)
208
240
277
VAC
Grid
voltage,
operating
range
(VAC)
244~304@277
VAC
212~264@240
VAC
184~228@208
VAC
Grid
frequency,
nominal
60
Hz
Grid
frequency,
operating
range
59.3~60.5
Hz
Maximum
output
power
6500W
7500W
Maximum
output
current
23.5A@277
VAC
27.1A@240
VAC
31.3A@208
VAC
27.1A@277
VAC
31.3A@240
VAC
36.1A@208
VAC
Output
over
current
protection
30A@277
VAC
35A@240
VAC
40A@208
VAC
35A@277
VAC
40A@240
VAC
50A@208
VAC
Maximum
output
fault
current
55
A
Grid
output
(AC)
Startup
current
<2A
Maximum
grid
backfeed
current
0
A
Waveform
True
sine
Power
factor
>0.99
@
nominal
power
Total
Harmonic
Distortion
<3%
DC
Component
<0.5%
Phase
Split
Phase
or
Single
phase
Solar
input
(DC)
Input
voltage
range
220~600
VDC
Input
voltage
range,
MPPT
230
V
~
500
VDC
Maximum
input
voltage
600
VDC
PV
start
voltage
(strike
voltage)
260
VDC
Maximum
input
current
35
A
Maximum
input
short
circuit
current
44
A
Number
of
fused
string
inputs
5
x
15A
Efficiency
Maximum
efficiency
96.7
%
@
277VAC
96.3
%
@
240VAC
96.0
%
@
208VAC
96.7
%
@
277VAC
96.5
%
@
240VAC
96.2
%
@
208VAC
CEC
efficiency
96.0
%
@
277VAC
96.0
%
@
240VAC
95.5
%
@
208VAC
96.0
%
@
277VAC
96.0
%
@
240VAC
95.5
%
@
208VAC
Night
‐
time
tare
loss
0.5W
Environmental
Operating
temperature
range
‐
25
°C
~
+50
°C
(
‐
13°
~
+122°F)
Storage
temperature
range
‐
25
°C
~
+65
°C
(
‐
13°
~
+149°F)
Maximum
full
power
operating
ambient
55
°C
(131°F)
50
°C
(122°F)
Relative
humidity
Max.
95%