Installation and Operation Manual (Rev E)
SGI Series Inverters
DOCR-060371
33
6.3
Screen Descriptions
Main Screen (Default)
Eac: XXXX kWh
Pac: XX W
Press
or
or
to move from the main / default screen into the Start Men
u. To enter into a
selected menu item, press the
key.
Start Menu
1.
Measurements
2.
Set Inverter
3.
Inverter Events
4.
Monitor
5.
RG Meter (if installed)
6.
Info
Measurements Menu
This displays the data retrieved from the inverter. Use the
buttons to scroll up and down
through the list.
Pressing
will take the screen back to the start menu.
AC Energy
Cumulative AC Energy (kWh)
AC Power
AC Power output (W)
AC Voltage
AC Voltage, Three-phase (V)
AC Freq.
AC Frequency (Hz)
AC Current (average)
AC Current, Three-phase average (A)
DC Voltage
DC Voltage (V)
Apparent Power
Apparent AC Power output (VA)
Reactive Power
Reactive AC Power output (VAr)
Reactive Avail.
Available Reactive AC Power output (Var)
React. Energy (+)
Cumulative reactive energy generated (kVArh)
React. Energy (-)
Cumulative reactive energy received (kVArh)
Heat Sink
Heat Sink Temperatures (
C) #1-3
DC Current #1-2
DC Current(A) #1- 2 (Only available with SolZone)
DC Current #3-4
DC Current(A) #3-4 (Only available with SolZone)
DC Current #5-6
DC Current(A) #5-6 (Only available with SolZone)
DC Current #7-8
DC Current(A) #7-8 (Only available with SolZone)
Note: data will only be available when inverter is awake and communicating.