Troubleshooting
B–3
The green LED is lit and a flashing I
appears on the dot matrix display when you
power on the system.
Check the seating of the Alpha VME 5/352
and 5/480 SBC CPU and I/O module
assembly, the seating of the breakout mod-
ules, and the seating of all VME devices.
Diagnostics pass but the SCSI tests take
more than 10 seconds to complete.
Check the SCSI termination, the seating of
the Alpha VME 5/352 and 5/480 SBC CPU
and I/O module assembly, the seating of the
breakout modules, the seating of the SCSI
cable, and the seating of all SCSI devices.
Diagnostics pass but there are no (or
unreadable) characters displayed on the
console.
Check the console terminal connections
and settings (9600 baud, 8-bits, no parity).
The terminal should be plugged into the
console (CON) port.
Table B–1 Troubleshooting Your SBC (Continued)
Symptom
Corrective Action