COLLECTOR MOUNTING.
-
5
INSTALLATION MANUAL SOLENE
®
HOT WATER SYSTEMS
©
2014 UMA Solar
FLUSH MOUNT GRIPPER INSTALLATION -
Parallel to the roof line, as illustrated below.
Fig. 1B
Start from the bottom. When elevating the collector to the roof, make sure that the “weep holes” are facing down. It is
recommended to install the collectors vertically (length up the roof’s slope), but the collectors may be installed horizontally as
well.
Flush Mount Installations are recommended when the roof’s slope conforms to the orientation and slope requirements as stated
previously. This is the easiest and most aesthetically pleasing installation method. After the collector(s) are installed, it should
resemble a skylight. The flush mount gripper (1-5060-030) consists of four (4) U-channels four (4) grippers, four (4) strut nuts with
springs, and associated hardware. There are two sets each for the top and bottom.
Once the collector’s location is determined, anchor two (2) U-channel to the roof using two (2) stainless steel 3/8” lag bolts
for each U-channel. Each bolt should be sealed using an appropriate roof sealant in order to prevent any possible leaks from
penetrating the roof members. The U-channel should be spaced so the lag bolts penetrate the roof trusses, and the U-channel
should run parallel to the truss. The collectors will rest on top of the U-channel. (Fig. 2)
1.
2.
Solene Aluminum Gripper Mount
3/8” Bolt - Washer - Nut Typ.
Solene Collector Typ.
Roof Truss
4. Collector Mounting.
- Cont.