6.
To exit the menu press the
button.
The application Defrost described cannot be used in Hong Kong in according with rules. The Solera ECO Soft
machine has to be empty and sanitized daily
.
Use of the TLI (Lower Limit Temperature)
If the machine is in “WAIT PLEASE” status, the product should not be ready to be served, but sometimes this might not
be true. If so, the customer can use the
TLI
function setting the correct temperature for the product.
In order to set the
TLI
see the following procedure:
1.
Press the
button on the electronic control panel to view the menu entries
2.
Press the
or
buttons until you reach the
TANK TEMPERAT.
screen
3.
If you press the
button, on the lower line of the display you can see the temperature of the product. In the
following example the temperature is -6,4°C/20.5°F
4.
Notice the temperature
5.
Press the
button to return to the previous screen
6.
Press the
or
buttons until you reach the
TLI
screen
7.
Press the
button to see the
TLI
temperature set on the control electronic board. In this example it is -
8,0°C/17.6°F
8.
Set the new
TLI
with the
or
buttons to the temperature reported at number
“4”
9.
After setting the temperature, press the
button
10.
To exit the menu press the
button
The TLI value can vary between a minimum of -8.5 °C (17.6°F) to a maximum of -1.0 °C (30.2°F).
Service submenu settings
Solera ECO Soft is supplied with a number of pre-established, default settings, which can be used for various products.
The settings are as follows:
Service step V1
V1= 50rpm (default)
T1= -8,5°C/16.7°F (default)
Service step V2
V2= 50rpm (default)
T2= -8,5°C/16.7°F (default)
Service step V3
V3= 30rpm (default)
RTS= not settable
RTS Time
10 minutes (default)
EV OFF Time
10 minutes (default)
> TANK TEMPERAT.
TLI
-8,0°C
TANK TEMPERAT.
-6,4°C
•
> TLI
TLI
-6,4°C
TANK TEMPERAT.
20.5°F
•
TLI
17.6°F
TLI
20.5°F
Summary of Contents for ECO Soft
Page 1: ... ENGLISH ESPAÑOL MANUAL DE USO Y MANTENIMIENTO USE AND MAINTENANCE MANUAL ...
Page 36: ... 35 Sistema Eléctrico Electric System ...
Page 38: ... 37 Sistema de Refrigeración Cooling System ...
Page 40: ... 39 Despiece Exploded View ...
Page 42: ... 41 ...
Page 43: ... 42 ...
Page 44: ... 43 ...
Page 47: ......