- 31 -
E
NGL
IS
H
Any modifications to these settings must be carried out by specialist and authorized personnel only.
In orde
r to reset SERVICE menu’s settings to their default, please follow below procedure:
1.
Make sure the machine is turned off; main switch (page.20 pos.F) in OFF position
2.
While holding
button on the front control board, turn the machine back ON. Release
button, when
control board’s screen shows
To modify the
SERVICE
settings, proceed as follows:
10.
To view the menu options, press the
key on the electronic control panel
Please note that on any menu, if a key is not pressed within 30 seconds, or if the
key is pressed again, the control
panel will automatically exit the menu. When this occurs, the electronic control unit will return to the previous screen.
11.
Use the
or
keys to search for the SERVICE screen.
12.
Hold the
key down for at least 6 seconds or until the first option of the SERVICE submenu appears on screen.
The display will flash and show the “
V1
” speed at which the augers must turn when the machine is switched on
until the machine has reached the “
T1
”temperature. The default settings are: V1=
50rpm and T1=-8,5°C/16.7°F
c.
Press the
or
keys to change the V1 “20 min. / max 70 in steps of 1rpm” settings.
d.
Press the
key to switch to the next T1 “
-8,5°C/16.7°F min. / max -
2,5°C/27.5°F in steps of 0,5°C/0.9°F”
setting
13.
Press the
key to confirm; the display will show the second option of the
SERVICE
submenu.
The display will flash and show the “
V2
” speed at which the augers must turn once the “
T1
” temperature has been
exceeded. Said velocity is maintained until the “
T2
” temperature is reached. The default values are: V2=
50rpm and
T2=-8,5°C/16.7°F
It is not possible to set a “T2” temperature that is higher than the “T1” temperature
.
a.
Press the
or
keys to change the V2 “20 min. / max 70 in steps of 1rpm” settings.
b.
Press the
key to switch to the next T2 “
-8,5°C/16.7°F min. / max -
2,5°C/27.5°F in steps of 0,5°C/0.9°F”
settings.
14.
Press the
key to confirm; the display will show the third option of the
SERVICE
submenu.
The display will flash and show the “
V3
” speed at which the augers must turn once the “
T2
” temperature has been
exceeded. Said velocity is maintained also during the “READY TO SERVE” product maintenance stage, unless the
machine is not dispensing. The default value is: V3=30rpm
> SERVICE
SERVICE STEP V1
V1rpm T1°C
SERVICE STEP V2
V2rpm T2°C
SERVICE STEP V3
V3rpm RTS
RESET OK
SERVICE STEP V1
V1rpm T1°F
SERVICE STEP V2
V2rpm T2°F
Summary of Contents for ECO Soft
Page 1: ... ENGLISH ESPAÑOL MANUAL DE USO Y MANTENIMIENTO USE AND MAINTENANCE MANUAL ...
Page 36: ... 35 Sistema Eléctrico Electric System ...
Page 38: ... 37 Sistema de Refrigeración Cooling System ...
Page 40: ... 39 Despiece Exploded View ...
Page 42: ... 41 ...
Page 43: ... 42 ...
Page 44: ... 43 ...
Page 47: ......