background image

 

 

For any questions or Technical Support, 

please call 

customer service 

877

-

665

-

9765

 

Self

-

Diagnosing 

Code

 

Description

 

Resolution

 

E1

 

Compressor Overheat Protec-

tion

 

Please call Soleus Customer Service at 877

-

665

-

9765

 

E2

 

Condenser Overheat Protection

 

Please call Soleus Customer Service at 877

-

665

-

9765

 

EH

 

Humidity Sensor Malfunction

 

Please call Soleus Customer Service at 877

-

665

-

9765

 

E5

 

Internal Pump Malfunction

 

NOTE: The internal pump is designed to be used with the 

included plastic drain tube with drain adapter and will not 

operate with a garden hose or any other tubing. (Figure 2)

 

     If you do not have a plastic drain tube and drain adapt-

er, please call Customer service for a replacement. 

 

First, be sure that the plastic drain tube and drain adapter are 

tightly and securely installed. Once installed, turn the unit off 

and unplug it to reset the E5 code. Wait 30 seconds and then 

plug in the unit and turn it on. The error code should be reset.

 

 

If the error code reappears after this process, please call So-

leus Customer Service at 877

-

665

-

9765

 

SELF

-

DIAGNOSING CODES

 

Figure 2

 

Summary of Contents for CBD-110P1A-J14A

Page 1: ...upright for 24 hours prior to operating This ensures that the compressor will function as intended CBD 70P1A H13A CBD 30H1A G13A CBD 45H1A G13A CBD 70H1A H13A CBD 95P1A J14A CBD 110P1A J14A Manufactu...

Page 2: ...efully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instruct...

Page 3: ...humidity level will become more and more stable Due to the stable humidity level in the area the dehumidifier will need to remove less and less moisture over time Please do not be concerned if the de...

Page 4: ...HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRE SENTED HEREWITHIN 1 Portable Dehumidifier 1 Operating Instructions 1 Pump Drain Hose Kit Hose Adapter and Gasket Adapte...

Page 5: ...es to WiFi networks Step 7 Choose Chigo SoleusAir device from list of available networks Step 8 Select WiFi Network you would like to use to control device Automatically routes back to the Chigo US Ap...

Page 6: ...audible alarm signals as soon as the bucket is full and ready to be emptied Ultra quiet operation allows for use almost anywhere Perfect for heavy traffic areas like a family room or bedroom Loss of p...

Page 7: ...MyHome Mode LED Indicators Power On LED Indicator Child Lock LED Indicator Bucket Full LED Indicator PUMP BUTTON INCREASE DECREASE ROOM HUMIDITY LEVEL PUMP Status LED Indicator Pump Drain Tube Connec...

Page 8: ...r increments up to 24 hours Once the desired time is reached the unit will automatically turn on Timer Auto Shut Off To program the unit to automatically turn off press the TIMER button when the unit...

Page 9: ...y normal The dehumidifier will not be removing moisture from the air at this time When removing moisture from the air the dehumidifier will exhaust warm air from the side exhaust vent Do not place a f...

Page 10: ...o the garden hose nozzle on the back of the unit as pictured below Drain adapter is included in storage compart ment on top of water bucket Once securely installed lead the Drain Hose to a nearby drai...

Page 11: ...ch may reduce performance Use the dehumidifier in cooking laundry bathing and dishwashing areas that have excessive moisture NOTE Place the dehumidifier away from a clothes dryer Use the dehumidifier...

Page 12: ...he cap on the back of the unit to access the garden hose nozzle Thread a garden hose not supplied onto the accessible nozzle lead to a floor drain and cut to length Make sure that there are no kinks o...

Page 13: ...ack in the unit and press the FILTER button to reset the filter indicator CAUTION DO NOT OPERATE THE DEHUMIDIFIER WITHOUT THE INCLUDED FILTER Clean the Unit Housing 1 Keep the unit from being exposed...

Page 14: ...ilter See the CLEAN FILTER section on Page 9 The Humidity Control may not be set low enough For drier air press the button to lower the percent humidi ty desired in the room or set the dehumidifier to...

Page 15: ...hange to a lower setting or empty the water bucket and replace properly Bucket is not in the proper position The bucket must be in place and securely seated for the dehu midifier to operate Power Fail...

Page 16: ...designed to be used with the included plastic drain tube with drain adapter and will not operate with a garden hose or any other tubing Figure 2 If you do not have a plastic drain tube and drain adap...

Page 17: ...handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those author...

Page 18: ...y energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a pa...

Reviews: