10
10)
Internal Pump Mode-
The internal pump allows the unit to operate without having to empty the bucket.
Included is a Drain Pump Hose Kit. To install the Pump Drain Hose Kit, open cover on the back of the
unit. Insert the included Gasket into the Drain Adapter. Force the Drain Hose onto the Drain Adapter. Lo-
cate the UPPER drain port on the back of the unit. Then install the Drain Adapter with Drain Hose onto the
upper drain port on the back of the unit as pictured below. Once securely installed, lead the Drain Hose to a
nearby drain, sink or out of a window up to 16’ height from the base of the unit. Turn on the unit and press
the PUMP button to activate the internal pump.
NOTE:
While in Pump Mode, if the unit is turned off, the pump will remove all remaining water from inter-
nal tank prior to the unit completely powering down, the pump indicator light will stay on in this period.
Please don't unplug power cord until pump indicator light is off.