background image

14 

 

Problem Possible 

Causes 

Solutions 

Dehumidifier does not 
start. 

The dehumidifier is un-
plugged. 

Make sure the dehumidifier’s plug is pushed com-
pletely into the outlet. 

The fuse is blown / circuit 
breaker is tripped. 

Check the house fuse / circuit breaker box and 
replace fuse or reset breaker. 

Dehumidifier has reached 
the user set humidity level 
or the bucket is full. 

The dehumidifier automatically turns off when either 
condition occurs. Change to a lower setting or 
empty the water bucket and replace properly. 

Bucket is not in the proper 
position. 

The bucket must be in place and securely seated for 
the dehumidifier to operate. 

Power Failure. 

There is a protective time delay of 3 minutes to 
prevent tripping of the compressor overload. For this 
reason, the unit will not start normal dehumidifica-
tion for 3 min. after it is powered back on. 

Dehumidifier is not oper-
ating as  
Intended. 

Not enough time    allowed 
for unit to remove moisture. 

When first installed, allow at least 24 hours to 
achieve the desired humidity level. 

 

Airflow is restricted. 

Make sure there are no curtains, blinds, or furniture  
blocking the side or back of the dehumidifier.  

 

Dirty filter. 

See the Cleaning The Air Filter section 

 

The user set Humidity Level 
may not be set low enough. 

To reduce moisture, press the down arrow button to 
lower the percent  humidity desired in the room, or 
set the dehumidifier to CO for continuous operation. 

 

Doors and windows may 
not be closed tightly. 

Check that all doors, windows, and other openings 
are securely closed. 

 

Water is not draining 
through drain hose 

Make sure the drain is placed below the drain con-
nector nozzle to allow gravity to drain the water 
(Refer to Gravity Drain Hose section in this manual). 

 

Room temperature is too 
low. 

Moisture removal is best at higher room tempera-
tures. Lower room temperatures will reduce the 
moisture removal rate. This model is designed to 
operate at temperatures above 41°F. 

Filter Indicator is lit. 

Filter needs to be cleaned 
every 250 hours of use. 

Once filter has been cleaned, press the FILTER but-
ton for 3 seconds to turn the filter indicator off. 

TROUBLESHOOTING 

7  

 

WATER DISPOSING OPTIONS 

 (Fig. 2) 

 (Fig. 3) 

OPTION 1: EMPTYING MANUALLY 
1.  Pull out the bucket, grasping the side handles. (Fig. 1) 
2. Carry the bucket by grasping the front corner of the bucket with one hand and the back of 

the bucket with the other hand( Fig. 2) 

3. Empty the bucket and replace the bucket in the dehumidifier. (Fig. 3) 
 
NOTE: Dehumidifier will not work and settings can not be changed when the BUCKET FULL 

indicator light is flashing or without the bucket properly installed. 

 (Fig. 1) 

DO NOT REMOVE THE STYROFOAM IN THE BUCKET 

 

This dehumidifier is equipped with a reliable Styrofoam float system. The Styrofoam 
located inside the float in the bucket is essential to the bucket full system working 
properly. Do not remove the Styrofoam from the float. 

Summary of Contents for DP2-70EP-03

Page 1: ...ADDRESS Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 WEBSITE www soleusair com TEL 888 876 5387 SG DEH 70EP 2 3 3 Portable Dehumidifier with External Pump Operating Instructi...

Page 2: ..._____________ _____________________________________________________________________ _____________________________________________________________________ ______________________________________________...

Page 3: ..._____________________________________________________________________ _____________________________________________________________________ ____________________________________________________________...

Page 4: ...he ground pin from the plug Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock 3 prong grounded plug Power supply cord...

Page 5: ...g this appliance KEY FEATURES WARNING CHOOSING THE PROPER LOCATION Use the dehumidifier in the basement to help prevent moisture damage in the kitchen laundry room bathroom and spa exercise areas that...

Page 6: ...f The 2 Hrs 7 timer indi cator will light up when the timer key is pressed Press the timer key once more for a 4 hour auto matic shut off The 4 Hrs 7 timer indicator will now light up Press the timer...

Page 7: ...desired in the room or set the dehumidifier to CO for continuous operation Doors and windows may not be closed tightly Check that all doors windows and other openings are securely closed Water is not...

Page 8: ...e back of the unit 2 Remove the filter and clean with warm soapy water Rinse and allow the filter to dry before placing back in the unit 3 Place the filter back into dehumidifier Plug unit back into o...

Page 9: ...e connections to make sure they are properly secured NOTE Make sure the drain hose is lower than the horizontal plane of the drain on the dehumidifier as seen in the illustration below Drain hose shou...

Page 10: ...g 13 FIG 12 FIG 13 OPTION 3 EXTERNAL VERTICAL PUMP INSTALLING THE EXTERNAL PUMP Step 1 To install Dehumidifier Drain Hose refer to Gravity Drain Using Dehumidifier Hose instructions starting on page 9...

Reviews: