This portable dehumidifier is designed for use in a single room and will 

have little or no effect on removing moisture from an adjacent space, such 

as a closet or hallway, unless there is adequate air circulation in and out of 

that area. 

 

 

Do not use outdoors. 

 

This dehumidifier is intended for indoor use only. Place the dehumidifi-

er on a smooth, level floor surface that is strong enough to support the 

unit with a full bucket of water. 

 

Allow at least 18” of air flow on all sides. 

 

Place the dehumidifier in an area where the temperature will not fall 

below 41°F. The coils can become covered with frost at temperatures 

below 41°F, which may reduce performance. 

 

Use the dehumidifier in cooking, laundry, bathing and dishwashing are-

as that have excessive moisture. NOTE: Place the dehumidifier away 

from a clothes dryer. 

 

Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored. 

 

Use the dehumidifier in a basement to help prevent moisture damage. 

 

The dehumidifier must be operated in an enclosed area to be most effective. 

 

Close all doors, windows and other outside openings to the room. 

When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run un-

til the frost disappears. When the coils are completely defrosted, the compressor will automatically restart and 

dehumidification will resume. 

CHOOSING A LOCATION

 

AUTOMATIC DEFROST

 

Summary of Contents for DSX-30M-01

Page 1: ...X 30M 01 DSX 45EM 01 DSX 70EM 01 70 Pints 30 Pints 45 Pints Portable Dehumidifier OPERATING INSTRUCTIONS Dehumidifier must be upright for 24 hours prior to operating This ensures that the compressor w...

Page 2: ...efully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instruct...

Page 3: ...sture accumulating in the air As this moisture level decreases the dehumidifier will not need to collect as much moisture as seen in previous operation Please do not be concerned if the dehumidifier i...

Page 4: ...able Dehumidifier 1 Operating Instructions 4 Casters Pre installed on 70 Pint Model Model Number DSX 30M 01 DSX 45EM 01 DSX 70EM 01 Dehumidifying Capacity 30 Pints per day 45 Pints per day 70 Pints pe...

Page 5: ...between maximum dehumidify ing power or quiet operation Bucket full indicator and audible alarm signals as soon as the bucket is full and ready to be emptied Ultra quiet operation allows for use almos...

Page 6: ...5 and forcibly insert the casters Make sure the ring around the caster is flush against the bottom of the dehumidifier Fig 3 POWER BUTTON INCREASE DECREASE ROOM HUMIDITY LEVEL TIMER BUTTON FILTER BUTT...

Page 7: ...4 hours Once the desired time is reached the unit will automatically turn on Timer Auto Shut Off To program the unit to automatically turn off press the TIMER button when the unit is on Each press of...

Page 8: ...not be removing mois ture from the air at this time When removing moisture from the air the dehumidifier will exhaust warm air from the side exhaust vent Do not place a full bucket on the floor becau...

Page 9: ...t at temperatures below 41 F which may reduce performance Use the dehumidifier in cooking laundry bathing and dishwashing are as that have excessive moisture NOTE Place the dehumidifier away from a cl...

Page 10: ...w the cap on the back of the unit to access the garden hose nozzle Thread a garden hose not supplied onto the accessible nozzle lead to a floor drain and cut to length Make sure that there are no kink...

Page 11: ...placing the filter Once the filter is complete ly dry place the filter back in the unit and press the FILTER button to reset the filter indicator CAUTION DO NOT OPERATE THE DEHUMIDIFIER WITHOUT THE IN...

Page 12: ...AN FILTER section on Page 8 The Humidity Control may not be set low enough For drier air press the button to lower the percent humidi ty desired in the room or set the dehumidifier to CO for max imum...

Page 13: ...cket is full The dehumidifier automatically turns off when either condi tion occurs Change to a lower setting or empty the water bucket and replace properly Bucket is not in the proper position The bu...

Page 14: ...ll customer service 877 665 9765 Self Diagnosing Code Description Resolution E1 Compressor Overheat Protection Please call Soleus Customer Service at 877 665 9765 E2 Condenser Overheat Protection EH H...

Page 15: ...ons in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by SOLEUS N...

Reviews: