Wiring Centre

MODEL:

 UFH8-RF

UH8-RF Wiring

Connections
Mains Supply

Power supply into the UH8-RF which should be fused at 5 amps 
these connections are marked

L = live or phase 230v AC 50/60Hz

N = Neutral

E = Earth

Boiler

This is the main call for heat for the system, there are 3 connections;

C = common

NO = normally open

NC = normally closed

Electrically this is a two-way switch, whatever supply is placed on 
the C connection, is fed to the NC connection when there is no call 
for heat. 
This is then switched to the NO connection when there is a call for 
heat. 

Most systems will use the common (C ) and normally open (NO) 
connections.

Pump

Used for an underfloor heating manifold pump.

Connections are clearly marked

L = live or phase 230v ac 50/60Hz

N = Neutral

E = Earth

When a thermostat configured as an under-floor heating zone 
sends a call for heat to the UH8-RF, the live output will supply 230v 
to the manifold pump.

It is recommended that this is fed through a high limit switch 
placed on the heating manifold, to protect against mechanical 
failure of the manifolds temperature control.

Valve

Used for an underfloor heating manifold valve.

Connections are clearly marked

L = live or phase 230v ac 50/60Hz

N = Neutral

E = Earth

When a thermostat configured as an under-floor heating zone 
sends a call for heat to the UH8-RF, the live output will supply 230v 
to the manifold valve.

H/W

This output is used to control a hot water cylinder thermostat

C = common

NO = normally open

NC = normally closed

Electrically this is a two-way switch, whatever supply is placed on the 
common connection, is fed to the NC connection when there is no 
call for hot water. This is then switched to the NO connection when 
there is a call for hot water.

Normally the NO connection would be wired to the hot water cylinder 
thermostat, then from there to the hot water valve, the valve auxiliary 
switch will then start the boiler/other heat source.

Most systems will use the common and normally open connections.

Zones 1…8

Zones outputs are clearly marked

L = live out to actuator or valve

N = neutral to actuator or valve

There are two connections live (L) and neutral (N), both terminals 
marked L are the same and both terminals marked N are the same.

Each zone output is numbered, Zone 1 will respond to radio signals 
from the thermostat paired to zone 1, Zone 2 output will respond to 
thermostat numbered 2 etc.

Fuses

Each UH8-RF is protected by 3 fuses

Fuse 1.

 800mA, 20mm anti-surge fuse, this fuse supplies and protects 

the internal electronics.

Fuse 2.

 5amp, 20mm anti-surge fuse, this fuse supplies power to all 

230v outputs from the board it protects the zone, pump and valve 
outputs.

Fuse 3.

 2amp, 20mm anti-surge fuse, this fuse supplies power to the 

pump and valve outputs, it protects the board from overloads caused 
by jammed valves or seized pumps.

The UH8-RF should be fitted as close as possible to the equipment it is controlling, but never within a metal enclosure, if this cannot be avoided an 
extension antenna (EA1) must be fitted and placed outside the metal enclosure.

Summary of Contents for UH8-RF

Page 1: ...MODEL UH8 RF ...

Page 2: ... signal is received from a hot water time clock on the system only the H W output will become active This is a timed output which is normally fed to a cylinder thermostat then to a valve but could also be used for towel rails In either case the valve auxiliary switch would operate the boiler other heat source Other functions Creepage During hot weather the heating is not normally needed as often t...

Page 3: ... cylinder thermostat C common NO normally open NC normally closed Electrically this is a two way switch whatever supply is placed on the common connection is fed to the NC connection when there is no call for hot water This is then switched to the NO connection when there is a call for hot water Normally the NO connection would be wired to the hot water cylinder thermostat then from there to the h...

Page 4: ...6 7 Wiring Centre MODEL UFH8 RF Wiring Diagram UH8 RF ...

Page 5: ...neers test switches These are a block of 12 dip switches used to test each zone boiler pump and HW outputs To enable any output put the switch in the ON position When installation is complete all switches MUST be in the OFF position Record the rooms names connected to each zone with the zone number and record the channel number you have selected you will need this information when installing the t...

Page 6: ...10 11 Wiring Centre MODEL UFH8 RF Notes System Configuration ...

Page 7: ...Want More Information Call our support team on 44 0 1268 744 249 cations directly on our website www solfexufh co uk Rev 1 0 Slimline Products Commonly used with the UH8 wiring centre NeoStat DS SB TM4 ...

Reviews: