2. SAFETY
>>
The heat generator may only be worked on by contractors.
>>
In accordance with VDE 0105 Part 1, work on electrical components may only be carried out by qualified electricians.
2.1 Intended use
Solid Air CPL ventilation units are designed to heat and filter normal air. The maximum air intake temperature is
+40 °C. The use of these units in wet rooms or rooms with explosive atmospheres is not permissible. Handling very dusty
or aggressive media is not permissible.
Any onsite modification or improper use of the unit is not permissible and Solid Air GmbH accepts no liability for any
damage caused as a result.
If additional protective equipotential bonding is required due to structural requirements, this should be provided
onsite. The user or the certified electrician is obliged to ensure correct earthing of the appliances in accordance with the
applicable national and local electrical and installation regulations.
A conductive or non-conductive connection can be established between modules depending on the appliance
configuration. Modules with electrical equipment must always be connected with the earth conductor.
Ventilation units intended for internal installation must be placed in rooms that meet the requirements of VDI 2050 (VDI
2050, Requirements for technical equipment rooms - Planning and execution). A contractor is defined as a qualified and
properly trained installer, electrician, etc.
The user is defined as somebody who has been trained to use the heat generator by a specialist.
The appliance may only be used up to an elevation of 2000 m above sea level.
The cables used in the unit are silicone-free and cadmium-free. They meet fire safety standards of class Eca (DIN 60332-2).
2.2 Safety measures
Never remove, bypass or otherwise disable any safety or monitoring equipment. Only operate the heat generator if it is in
perfect technical condition. Any faults or damage that impact or might impact safety must be remedied immediately by a
qualified contractor.
>>
All faulty components must be replaced with original Solid Air spare parts.
It may only be used for handling air. This air must not contain any harmful, combustible, explosive, aggressive, corrosive or
otherwise dangerous substances, as these would be distributed throughout the duct system or building, where they could
cause a risk to the health of, or even kill the occupants, animals or plants living there.
2.2.1 What to do in the event of a fire
The unit does not present a direct risk of fire. The small numbers of seals fitted inside the unit can burn away if subjected
to external influences.
>>
If there is a fire, disconnect the appliance from the power supply using the onsite smoke detector.
>>
Wear respiratory equipment if you fight a fire.
>>
Use standard extinguishing agents such as water, extinguishing foam or extinguishing powder..