Engineering Measures 

Ensure adequate ventilation, especially in confined areas. Ensure that 
eyewash stations and safety showers are close to the workstation location. 

 

Personal Protective Equipment 

      Eye/face Protection

  

Wear appropriate protective eyeglasses or chemical safety goggles as 
described by OSHA's eye and face protection regulations in 29 CFR 
1910.133 or European Standard EN166. 

      Skin and body protection

  

Wear appropriate protective gloves and clothing to prevent skin exposure.   

      Respiratory Protection

  

Follow the OSHA respirator regulations found in 29 CFR 1910.134 or 
European Standard EN 149. Use a NIOSH/MSHA or European Standard 
EN 149 approved respirator if exposure limits are exceeded or if irritation or 
other symptoms are experienced. 

      Hygiene Measures

 

Handle in accordance with good industrial hygiene and safety practice. 

 

9. Physical and chemical properties 

 
Physical State

  

Viscous liquid Liquid 

Appearance

  

Colorless 

Odor

  

Odorless 

Odor Threshold

  

No information available 

pH

  

5.5-7.5 50% aq. sol 

Melting Point/Range

  

-13 °C / 8.6 °F 

Boiling Point/Range

  

196 - 198 °C / 384.8 - 388.4 °F @ 760 mmHg 

Flash Point

  

111 °C / 231.8 °F 

      

Method -

  

DIN 51758 

Evaporation Rate

  

No information available 

Flammability (solid,gas)

  

Not applicable 

Flammability or explosive limits 

      

Upper 

 

15.30 vol % 

      

Lower 

 

3.20 vol % 

Vapor Pressure

  

0.12 mmHg @ 20 °C 

Vapor Density

  

2.14 (Air = 1.0) 

Specific Gravity

  

1.113 

Solubility 

 

miscible 

Partition coefficient; n-octanol/water

  

No data available 

Autoignition Temperature

  

413 °C / 775.4 °F 

Decomposition Temperature

  

> 500°C 

Viscosity 

 

21 cP (20°C) 

Molecular Formula

  

C2 H6 O2 

Molecular Weight

  

62.06 

 

10. Stability and reactivity 

Reactive Hazard

  

None known, based on information available 

Stability 

 

Hygroscopic. 

Conditions to Avoid

  

Incompatible products. Excess heat. Exposure to moist air or water. 

Incompatible Materials

  

Strong oxidizing agents, Strong acids, Strong bases, Aldehydes 

Hazardous Decomposition Products

  Carbon monoxide (CO), Carbon dioxide (CO2) 

Hazardous Polymerization

  

Hazardous polymerization does not occur. 

Hazardous Reactions

  

None under normal processing. 

 
 

Summary of Contents for THERMORACK 800

Page 1: ...Precision Thermal Control for Optimal Laser Performance and Stability THERMORACK800 Product Manual...

Page 2: ...2 OPERATION _______________________________________________________________________ 12 5 1 Simple Operation _____________________________________________________________ 12 5 2 Advanced Operation ____...

Page 3: ...ur sole responsibility that the ThermoRack 800 All Models meets the provisions of the directives 2004 108 EC EMC Directive 2006 95 EC Low Voltage Directive EN 61326 1 2006 Emissions and Immunity EN 61...

Page 4: ...tor only trained personnel may interact with internal components Caution Heavy object System weighs 55 lbs 25 kg Two people are required to lift CAUTION Never disassemble the chiller as irreparable da...

Page 5: ...The red WARNING equilateral triangle symbol appears throughout the manual accompanying certain maintenance and repair activities Please follow the important instructions accompanying this symbol to a...

Page 6: ...3 5 liters per minute of constant temperature coolant with PID control for both cooling and heating With fewer moving parts the system is highly reliable and energy efficient The ThermoRack 800 has b...

Page 7: ...ms with centrifugal pumps as water absorbs CO2 from the air causing its pH to become acidic Acidic water dissolves copper which then plates out inside the magnetic drive of the centrifugal pump causin...

Page 8: ...ID STATE COOLING SYSTEMS 167 MYERS CORNERS ROAD WAPPINGERS FALLS NY 12590 7 TELEPHONE 845 296 1300 FAX 845 296 1303 WEB WWW SSCOOLING COM VERSION M8 Figure 1 ThermoRack 800 Cooling Capacity in 20 C Am...

Page 9: ...6 1300 FAX 845 296 1303 WEB WWW SSCOOLING COM VERSION M8 SECTION 3 HOOK UP _______________________________________________________ Figure 3A Front View Figure 3B Rear View with 5X20 10A fast acting fu...

Page 10: ...ance is required in front and in back to ensure adequate airflow 3 2 ELECTRICAL CONNECTIONS SEE FIGURES 3A AND 3B Power The ThermoRack 800 AC power inlet is an IEC320 C20 socket Plug the line cord pro...

Page 11: ...k adding coolant as required to maintain the tank level just below maximum 4 Replace tank cap Recommended Coolants Solid State Cooling Systems recommends using Koolance a pre mixed 27 propylene glycol...

Page 12: ...hiller on via the switch located on the front Fluid should begin flowing into the bucket If it does not turn off the chiller wait 30 seconds then turn the chiller back on Once fluid begins flowing tur...

Page 13: ...operating turns off temperature control 5 1 SIMPLE OPERATION The ThermoRack 800 comes with preset operating parameters that will work well for most applications If temperature control at one temperatu...

Page 14: ...several user adjustable parameters To access this menu press and hold the ENTER button for 3 seconds and then enter password 0000 using the UP DOWN and ENTER keys This menu allows access to the follo...

Page 15: ...on scale up 2 C to match the external sensor TEMPUNIT Sets temperature units in degrees Celsius or Fahrenheit BKLIGHT Setting this parameter to ON turns on the display back light setting this paramete...

Page 16: ...t the front and rear air inlet and outlet gratings are not blocked If airflow is not blocked contact SSCS for an RMA number to return the unit for fan replacement Pump Fail The liquid heat exchanger p...

Page 17: ...Format ASCII Insert a carriage return 0x0Dhex at the end of each command string A carriage return 0x0Dhex is sent at the end of each response Table 2 USB Commands PARAMETER GET Data Command Response...

Page 18: ...3 Cr 69 2 Cr 119 Cr 7 Cr 0 Cr ETX STAT1A Bit Field Definition convert decimal number sent into binary read as follows __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ ___Chiller Running 1 RUNNING 0 STO...

Page 19: ...inal Equipment DTE Table 1A Signal definition and wiring for Host wired as DTE Computer Host Master Male 9 Pin D sub Pin Chiller Slave Female 9 Pin D sub Pin 2 Receive RXD 2 Transmit TXD 3 Transmit TX...

Page 20: ...erature PUMPTEMP XX X Actual TE PWM PWM XX X Status word 1 5 ASCII bytes STAT1A 0 65535 Faults word 1 5 ASCII bytes FLTS1A 0 65535 Reset All Alarms and Restart RESTART GETSET2 parameters GETSET2 retur...

Page 21: ...NG 0 COOLING ___________________ genwarning 1 WARNING 0 NONE ______________________ genalarm 1 ALARM 0 NONE _______ rsvd ____ __________________________ autotune 1 ON 0 OFF FLTS1A Bit Field Definition...

Page 22: ...xterior surfaces of the ThermoRack 800 may be cleaned with a non shedding wipe dipped in isopropyl alcohol SECTION 9 TECHNICAL SUPPORT _____________________________________________ Delighting our cust...

Page 23: ...ized System of Classification and Labeling of Chemicals GHS Physical Hazard Not applicable Health Hazard Skin Irritation Category 2 Eye Irritation Category 2 Environmental Hazard Not applicable Label...

Page 24: ...on and immediately contact emergency medical assistance If ingested Never give anything by mouth to an unconscious person Rinse mount with water and consult a medical doctor immediately Other medical...

Page 25: ...age KOSHA No data available US ACGIH No data available Appropriate engineering controls Respiratory protection Approved respirator equipped with cartridge for organic vapors Eye protection Protective...

Page 26: ...ratory sensitization No data available Skin sensitization No data available Germ cell mutagenicity No data available Carcinogenicity Not classifiable from IARC EC ESIS Reproductive Toxicity No data av...

Page 27: ...S US NLM Toxic and ecological information OECD SIDS IUCLID US NLM IARC EC ESIS CCRIS Acronyms and Websites EC ESIS European chemical Substances Information System http esis jrc ec europa eu IUCLID Int...

Page 28: ...use Details of the supplier of the safety data sheet Company Fisher Scientific One Reagent Lane Fair Lawn NJ 07410 Tel 201 796 7100 Emergency Telephone Number CHEMTREC Inside the USA 800 424 9300 CHEM...

Page 29: ...sposal Dispose of contents container to an approved waste disposal plant Hazards not otherwise classified HNOC WARNING Reproductive Harm https www p65warnings ca gov 3 Composition Information on Ingre...

Page 30: ...breathing apparatus pressure demand MSHA NIOSH approved or equivalent and full protective gear NFPA Health Flammability Instability Physical hazards 2 1 1 N A 6 Accidental release measures Personal P...

Page 31: ...nd safety practice 9 Physical and chemical properties Physical State Viscous liquid Liquid Appearance Colorless Odor Odorless Odor Threshold No information available pH 5 5 7 5 50 aq sol Melting Point...

Page 32: ...ot listed Not listed Not listed Mutagenic Effects No information available Reproductive Effects No information available Developmental Effects No information available Teratogenicity No information av...

Page 33: ...Section 5 e Consent order under TSCA F Indicates a substance that is the subject of a Section 5 f Rule under TSCA N Indicates a polymeric substance containing no free radical initiator in its invento...

Page 34: ...e Pollutant N U S Department of Homeland Security This product does not contain any DHS chemicals Other International Regulations Mexico Grade Slight risk Grade 1 16 Other information Prepared By Regu...

Page 35: ...ent installation storage or usage occurring during a situation specifically cautioned against or noted in the product manual Specific situations which invalidate the warranty include but are not limit...

Reviews: