Installation Wiring
Section 5
Page 43
Meters and Phasescope
A Centre Section of the C300HD console can optionally be equipped with six off analogue VU meters with screening for
5.1 monitoring channels. In addition, each Centre Section may be fitted with an LCD phasescope. Two standard phasescope
types are available, the MSD600C or the RTW 10830. Other custom meter solutions may be possible. Note that if the
number of mechanical VU meters fitted is increased to eight, then there is no longer room for a phasescope.
Cable connections to the meters and phasescope will need to be run between the Centuri and the Console. Both balanced
analogue and 110Ω digital cables may be necessary depending on configuration. These cables are not supplied by SSL.
The MSD600C 5.1 phasescope has inputs for 6 digital signals (3 AES/EBU pairs), plus a serial diagnostic port.
The RTW 10830 has eight digital input signals, eight digital output signals, eight analogue input signals plus a remote control
port. Note that the analogue input signals would normally feed both the phasescope and the mechanical meters.
The signals for the Analogue meters could be paralleled from the console main output signals or, alternatively, independent
feeds from the analogue output card.
Refer to page 53 for the analogue meter wiring pinout and page 54 for the digital wiring.