Physical *
Depth
310mm / 12.25" (7 RU)
height when rack mounted
Height
120mm / 4.75"
depth in rack
Width
434mm / 17.1"
casing only
484mm / 19"
including rack ears
Weight
4.8kg / 10.5 pounds
Power
<
50 Watts
Boxed size
500mm x 385mm x 190mm
19.75" x 15.2" x 7.5"
Boxed weight
6.6kg / 14.5 pounds
* All values are approximate
Environmental
Temperature Operating: +5 to 30 deg. C
Non-operating: –20 to 50 deg. C
Max. gradient: 15 deg. C/hour
Relative Operating: 20 to 80%
Humidity Non-operating: 5 to 90%
Max. wet bulb: 29 deg. C
(non-condensing)
Vibration Operating:
<
0.2 G (3 – 100Hz)
Non-operating:
<
0.4 G (3 – 100Hz)
Shock Operating:
<
2 G (10ms max.)
Non-operating:
<
10 G (10ms max.)
Altitude Operating: 0 to 3000m
(above sea level) Non-operating: 0 to 12000m
Connections
Power
IEC320 3-pin connector, 100 – 240 Vac, 50 – 60 Hz
I/O
25-pin D-type socket, Zi
>
10k
Ω
, Zo
≈
100
Ω
Performance
Channel Line/Alt In to Channel Out (post fader):
Frequency Response 10Hz – 40kHz
±
0.2dB
THD+N
<
0.05% (20Hz – 20kHz)
Noise
<
–83dBu (20Hz – 20kHz)
Headroom
>
+24dBu (into 10k
Ω
)
Channel Line/Alt In to Mix Buss (single fader):
Frequency Response 10Hz – 40kHz
±
0.3dB
THD+N
<
0.05% (20Hz – 20kHz)
Noise
<
–77dBu (20Hz – 20kHz)
Headroom
>
+24dBu (into 10k
Ω
)
Electro Magnetic Compatibility
EN55103-1:2009, EN55103-2:2009
Environments E1, E2, E3 and E4
Initial in-rush current
7.16A
5 sec in-rush current
7.16A
Braid-screened cables should be used where applicable
Star Quad cables should be used where applicable
EMC Performance Criteria
Line level inputs and outputs
Measure at mid-gain, noise
<
–56dBu
Summary of Contents for X-Panda
Page 2: ......
Page 10: ...6 ...
Page 16: ...12 ...
Page 22: ...18 ...
Page 28: ...24 ...
Page 34: ...30 ...
Page 40: ...36 Basic X Panda Example Complete System ...
Page 41: ...37 EN DE ES FR IT JP Cascaded X Panda Example Cascade with X Desk ...
Page 42: ...38 Additional X Panda Example Use With Alternative Mixer ...