N2ROU Wall Mount Procedure 

 

The enclosure comes with the bracket for wall mounting. It doesn’t need to remove the bracket 

to  install the  enclosure,  simply  install  and  tighten  4 mounting  bolts  to  secure  the  unit.  First, 

install 2 of M12 mounting bolts roughly half way into the wall. Mount the enclosure and tighten 

the bolts. Second, tighten the remaining M12 mounting bolts under the enclosure and secure 

the unit tightly. 

 

 

Figure 4.4 – Installation Procedure 

 

 

 

 

Summary of Contents for Alliance N2ROU

Page 1: ...fidential Proprietary 1 28 Alliance_N2ROU Remote Unit User Manual SOLiD Inc 10 9th Floor SOLiD Space220 Pangyoyeok ro Bundang gu Seongnam si Gyeonggi do Korea 393 400 Tel 82 31 627 6290 Fax 82 31 627 6209 ...

Page 2: ...vice International Copyright This manual is written and produced by SOLiD and printed in the USA All rights are reserved 2015 SOLiD Confidential and proprietary Information contained in this document is company private to SOLiD and should not be modified used copied reproduced or disclosed in whole or in part without the written consent of SOLiD Technical Support SOLiD serial numbers must be avail...

Page 3: ...3 3 1 Functional Description 3 2 N2ROU Component 9 3 3 Dimension 11 Section4 4 1 Installation 12 4 3 Install N2ROU 12 4 3 1Install N2ROU 12 4 3 2N2ROU Power Cabling 16 4 3 3N2ROU Ground Cabling 18 4 3 4Optical Cabling 20 4 3 5Installing AOR Optional 21 Section5 5 1 Specifications 25 5 2 RF Performance 26 5 3 Certification 26 ...

Page 4: ... the door or cover in an open position to prevent the door from slamming shut in windy conditions Use this unit only for the purpose specified by the manufacturer Do not modify or fit any spare parts that are not sold or recommended by the manufacturer This could cause fires electric shock or other injuries Do not operate this unit on or close to flammable materials as the unit may reach high temp...

Page 5: ...age protection device Only 50 ohm rated antennas cables and passive equipment shall be used with this remote Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi directional system All components connected to this device must operate in the frequency range of this device Only 50 ohm rated antennas cables and passive components operati...

Page 6: ...ntenna after accounting for any cable losses should be less than 2 dBi Notice Be careful not to touch the Heat sink part due to high temperature Use of unauthorized antennas cables and or coupling devices not conforming with ERP EIRP and or indoor only restrictions is prohibited Home personal use are prohibited Signal booster warning label statements FCC IC WARNING This is NOT a CONSUMER device It...

Page 7: ...Multi use stadiums convention centers etc The system helps improve in building radio environments in poor condition and make better poor RSSI and Ec Io By providing communication services at every corner of buildings the system enables users to make a call at any site of buildings The system uses both analog AMPS and digital TDMA CDMA WCDMA and LTE methods The N2ROU system supports communication s...

Page 8: ... and it supports 2W output power for each band except 2 5TDD module For 2 5TDD and 2 5TDD M modules they need 1 6W output power The N2ROU has two types of multiplexers one for supporting 5 band and one for 7 band Based on the required frequency choose one of them for service 5 band Multiuplexer 600 RX Only 700M 800M 1900M 2100M 2 5TDD 7 band Multiuplexer 600 RX Only 700M 800M 1900M 2100M 2 5TDD 23...

Page 9: ...re amplified through High Power Amp in a corresponding RDU combined with Multiplexer module and then radiated to the antenna port RX signals received from the antenna port are filtered through the multiplexer module amplified at the RDU modules and converted into optical signals via optical module After converted the signals are sent to a upper device of ODU or iODU Four base bands are installed a...

Page 10: ...ise versa Compensate optical loss Communicate with legacy BIU or iBIU OEU though the FSK modem 5dBo optical link between ODU OM4 and ROU 10dBo optical link between ODU OM1 and ROU Fiber Connector SC APC Connector Fiber Type Single Mode Fiber Optical Wavelength 1310 1550 WDM RCPU Remote Central Processor Unit Controls signal of each unit Monitors legacy BIU or iBIU ODU OEU through the FSK modem MUX...

Page 11: ... Enclosure to satisfy IP66 Vertical Mount Wall Mount 3 1 Dimension Figure 3 6 Remote Unit Dimension ITEM SPECIFICATION REMARK Dimensions WxHxD 18 5 x16 5 10 RU x 10 2 470mm x 420mm x 260mm Including Bracket Weight Max 73 lbs 33kg for base model 4 bands Max 86 lbs 39kg for 7 bands MUX included ...

Page 12: ...r cabling method and optical cabling and RF interface Required accessories and tools for installation are list up in the below table 4 2 Install N2ROU 4 2 1 Install N2ROU The N2ROU uses a unibody enclosure that is NEMA 4 IP66 certified to withstand water and dust intrusion It can be mounted on a pole wall or rack Basically wall mounted bracket for N2ROU is included Figure 4 1 Exterior of N2ROU ...

Page 13: ...Confidential Proprietary 13 28 Figure 4 2 N2ROU Wall Mount Dimensions Figure 4 3 N2ROU Rack Mount Dimensions ...

Page 14: ...the bracket to install the enclosure simply install and tighten 4 mounting bolts to secure the unit First install 2 of M12 mounting bolts roughly half way into the wall Mount the enclosure and tighten the bolts Second tighten the remaining M12 mounting bolts under the enclosure and secure the unit tightly Figure 4 4 Installation Procedure ...

Page 15: ...EA N2RDU N2RDU_781921 N2RDU_2300 N2RDU_2500TDD N2RDU_600 ANT1 N2RDU_2500TDD_M ANT2 MUX_5B Internal Combiner Unit for 600RX 700 800 850 1900 2100 and 2500 1EA MUX_7B Internal Combiner unit for 600 700 800 850 1900 2100 2500 2300 and 600TX 1EA DUP Kit 2500TDD_DUP Kit BPF Kit 2500TDD_BPF Kit Basically the N2ROU is equipped with RCPU to check and control state of each module R_OPTIC to covert RF to op...

Page 16: ...ption of AC port is as below Pay attention to the correct polarity AC Power Port MS Connector No Name Description A AC_H AC Hot B AC_N AC Neutral C N C Not Connected D F G Frame Ground Check if the connection is the same as one seen in the table above and make sure to turn the power ON The figure below is the AC power cable that comes with the unit Figure 4 5 AC Power Cable ...

Page 17: ...f DC port is below Pay attention to the correct polarity DC Power Port MS Connector No Name Description A N C Not connected B N C Not connected C V 48V D V 48V Check if the connection is the same as one seen in the table above and make sure to turn the power ON The figure below is the DC power cable included in the package Figure 4 6 DC Power Cable ...

Page 18: ...ttom of N2ROU enclosure fixed by an M6 screw Compression terminal is attached already when it is delivered The recommended thickness of cable is AWG 6 copper grounding wire Figure 4 7 Location of Ground Terminal The specification of compression terminal is as follows Figure 4 8 Information of Terminal ...

Page 19: ...teps below Figure 4 9 Installing Ground Terminal The procedures are 1 Loosen two M6 screws and then take compression terminal off 2 Insert AWG 6 grounding wire into terminal and then compress a terminal using the tool 3 Assemble the terminal with 2xM6 screws 4 Cut the ground wire to proper length and connect it to the earth ground source ...

Page 20: ...ptical connector is located at the bottom of the N2ROU Optical cable can be connected by using its connectors Figure 4 10 Optical Connector Refer to the figure below for detailed information The figure is based on LC type but can be applied to SC type as well ...

Page 21: ...nit To install and connect the N2ROU with AOR the materials listed blow are required Accessory Description Qty Specification Remark 1 Inner I O Cable 1 MS 3106A 14S 5P M ST to SMH200 F ST_0 5m 2 Inner RF Cable 2 N F ST to SMBL M ST_0 18m 3 I O Cable 1 IEC 61076 2 101 8pin_F ST_1 5m 4 RF Cable 2 N M ST to SMA M ST_1 5m ...

Page 22: ...Confidential Proprietary 22 28 To connect AOR with the N2ROU the steps listed blow must be done in advance ...

Page 23: ...ports are circled in red Use the same method of No 1 to remove the dummy cover 3 Install the inner I O cable with the screws included in the package Pay special attention to the direction of connector when intalling them 4 Connect the inner I O cable to the defined connector of the RCPU 5 Install two inner RF cables with the screws included in the package 6 Check the names of the ports Match and c...

Page 24: ...fter the preliminary work For legacy BIUand eBIU do not need this preliminary work but for the new version the preliminary work is required in order to connect AOR For connecting AOR with the N2ROU pay attention to the cable length The cable length between the N2ROU and AOR is 1 5m Figure 4 24 Connecting Diagram between N2ROU and AOR ...

Page 25: ...raft Port Serial interface RS 232 9 pin D sub Male for connecting management PC on CPU In Output Port Type N Female for connecting AOR Power Consumption 165W for based model with 4 bands Maximum 260W for 6 bands Max 300W for 7 bands if 600 is included Environmental Specification Environmental IP Rating IP66 Compliant NEMA4 Operating Environment Temp Range 10 C to 50 C Humidity 5 to 90 non condensi...

Page 26: ...RX MHz N2RDU_781921 39 17 21 33 5 729 768 699 716 B1 777 798 B2 32 32 33 5 862 894 817 849 65 65 33 5 1930 1995 1850 1915 70 70 33 5 2110 2180 1710 1780 N2RDU_2300 10 10 33 5 2350 2360 2305 2315 N2RDU_2500TDD 71 2 LB UB 37 8 MB 32 5 2496 8 2568 LB 2574 1 2611 9 MB 2618 8 2690 UB N2RDU_2500TDD_M N2RDU_600 5 10 20 33 5 617 652 663 698 5 3 Certification Environmental Specification Environmental IP Ra...

Page 27: ... operated with a minimum distance of 250 cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter RF exposure will be addressed at time of installation and the use of higher gain antennas require larger separation distances Max antenna gain DL 17 dBi RSS GEN SEC 7 1 2 TRANSMITTERS Under Industry Canada regulatio...

Page 28: ... chaque type d antenne Les types d antenne non inclus dans cette liste ou dont le gain est supérieur au gain maximal indiqué sont strictement interdits pour l exploitation de l émetteur RF RADIATION EXPOSURE This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 250 cm between th...

Reviews: