GENERAL
Problem
Reason
Solution
The forks cannot be
lifted to the maximum
height
Overloading of the max. load capacity
The maximum load capacity is indicated on the rating plate
Battery is too weak
Charging the battery
The fuse is out
Check and possibly replace the fuse
The hydraulic oil is not sufficient
Check and if necessary top up the hydraulic oil
The oil pressure is too low; oil leaks
Check and if necessary replace sealing hoses
and / or cylinder
No oil
Oil level is too low
Increase the oil level
The forks cannot
be lowered
Shut-off valve is dirty/blocked
Check the hydraulic oil and cleaning control valve.
Change the hydraulic oil as necessary.
Removing electromagnetic valve opens or
is damaged
Check or replace solenoid valve
The truck does not
respond
The battery is being charged
When the battery is fully charged Pull
the power plug.
The battery is not connected
Connect the battery correctly to the charger
The fuse is out
Check the fuse and replace it
where appropriate.
Low battery
Charging the battery
The emergency stop switch is activated
Pull the button to reset the emergency stop
The drawbar is not in the correct position
Moving the tiller out of the braking zone
Forklift only travels in
one direction
Accelerator / connections are damaged
Check the accelerator and the connection
Stacker runs
very slowly
Low battery
Check the charge level of the battery and charge it
The electromagnetic brake is activated
Release the electromagnetic brake
The drawbar is not connected correctly or the cable is damaged
Check wiring
The truck suddenly
starts
Damage to the controller
Replace the controller
The accelerator is not returned to the center position
Repair or replace the accelerator
TROUBLESHOOTING