Manual - BlueGEN BG-15 Generic Installation Manual - Europe
© SOLIDpower GmbH 2019
30
ErP data
Seasonal space heating energy efficiency
class
A
++
Seasonal space heating energy efficiency
490% (according EN 50465:2015)
Sound power level
< 52 dB(A)
according EN 15036-1
Supply requirements
Fuel supply
Natural gas (methane)
Appliance Type
I2L / I2H / I2N / I2E / I2E
+
/ I2ELL
Fuel input
H
i
= 3.3 kW; H
s
= 3.6 kW
Natural gas pressure
Range of 9
–
30 mbar (0.9
–
3.0 kPa)
Gas connection
R
p
½” ½” BSPP fe ale
Water supply connection
¼” LLDPE hose o e ti g to Joh Guest fitti g
Water input
up to 36 Litres per day (at 1.5 kWe output)
Water supply pressure
Minimum 1.0 bar (100 kPa)
Maximum 10 bar (1000 kPa)
Drain connection
Wastewater
—
3/8
”
LLDPE hose (ejected from the unit
under pressure 0
–
1.0 bar (0-100 kPa)
Overflow and overpressure water
—
3/8
”
LLDPE hose
Both connecting to
½ BSPP
fittings
Heat recovery circuit
–
water supply
pressure
Range of 0
–
2.0 bar (0
–
200 kPa)
Maximum 3 bar (300 kPa)
Heat recovery circuit
–
water supply
temperature
Maximum 80 °C
Heat recovery circuit
–
water supply flow
Nominal 2 Litres per minute
Heat recovery circuit
–
inlet and outlet
connections
R
p
¾” ¾” BSPP fe ale
Operation
Starting
Fully automatic start
Stopping
Fully automatic shutdown
Compliance
Emissions from fuel cell stack
H
2
O + CO
2
CE
Yes
NOx class
6
Serviceable items
Routine
Cold desulphurisation catalyst (internal)