background image

 

2. Features 

 

Pure sine wave output (THD 

< 3%

)

 

 

Output frequency

50 / 60Hz switch selectable 

 Input & output fully isolation design 

 High efficiency 88~94% 

 Capable of driving highly reactive & capacitive loads at start moment. 

 Tri-Color indicators display input voltage & output load level 

 Loading controlled cooling fan 

 Advanced microprocessor 

 Protection

Input low voltage         Overload                    Short circuit           

                      Low battery alarm         Input over voltage      Over temperature 

 

2-1. Application 

2-1-1. Power tools – circular saws, drills, grinders, sanders, buffers, weed

 

and hedge trimmers, air compressors.

  

2-1-2. Office equipment – computers, printers, monitors, facsimile machines, 

scanner. 

2-1-3. Household items – vacuum cleaners, fans, fluorescent and  

incandescent lights, shavers, sewing machines. 

2-1-4. Kitchen appliances – coffee makers, blenders, ice markers

2-1-5. Industrial equipment – metal halide lamp, high – pressure sodium lamp. 

2-1-6. Home entertainment electronics – television, VCRs, video games,  

stereos, musical instruments, satellite equipment. 

 

2

 

 

Summary of Contents for S600 Series

Page 1: ...S600 S600R Series Pure Sine Wave Inverter User s Manual ...

Page 2: ...d testing 10 11 3 5 AC Safety Grounding 12 13 3 6 Making DC Wiring Connections 13 14 3 7 Inverter Operation 15 4 Troubleshooting guide 16 5 Maintenance 17 6 Warranty 17 7 Appendices 18 7 1 CE LVD EN60950 Declaration of Conformity 18 7 2 FCC Class B Declaration of Conformity 19 7 3 e mark e13 020866 Declaration of Conformity 20 21 7 4 UL UL458 NOTICE OF COMPLETION 22 Copyright This manual is the co...

Page 3: ...or Flammable materials or in locations which require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connection between components of the fuel system 1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flood ey...

Page 4: ... alarm Input over voltage Over temperature 2 1 Application 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors 2 1 2 Office equipment computers printers monitors facsimile machines scanner 2 1 3 Household items vacuum cleaners fans fluorescent and incandescent lights shavers sewing machines 2 1 4 Kitchen appliances coffee makers blenders ice mark...

Page 5: ...40V RMS 10 4 Input Voltage Regulation 10 5 15 VDC 21 0 30 VDC 42 60 VDC 10 5 15 VDC 21 0 30 VDC 42 60 VDC Input Level Indicator Load Level Indicator Red Orange Green LED Failure Indicator Red LED Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Safety UL458 EN60950 EMC FCC Class B EN50081 1 1992 EN50082 1 1992 EN55022B 1994 EN61000 4 2 1995 EN61000 ...

Page 6: ...2 3 Mechanical Drawings P U R E S IN E W A V E IN V E R T E R 4 ...

Page 7: ...n this model 3 1 Front Panel Operations 3 1 1 Front view P U R E S IN E W A V E IN V E R T E R 3 1 2 ON OFF switch Power ON OFF switch leave in the OFF position during installation 3 1 3 Input Level Display Input Voltage LED Status DC 12V DC 24V DC 48V Red Blink Slow 10 5 10 9 21 0 21 8 42 0 43 6 Red 10 9 11 3 21 8 22 6 43 6 45 2 Orange 11 3 12 0 22 6 24 0 45 2 48 0 Green 12 0 14 0 24 0 28 0 48 0 ...

Page 8: ...d 450W 580W Red Blink Over 580W 3 1 5 Fault Display fault status Red LED Conditions Status Blink Fast OVP Blink Slow UVP Blink Intermittently OTP Blink Solid OLP 3 1 6 AC outlet Outlet sockets available North America GFCI North America Continental European SCHUKO Australia New Zealand United Kingdom Universal 6 ...

Page 9: ...mote ON OFF switch to operate inverter ON OFF switch on the Front Panel must be off 3 2 1 2 Make sure the remote control contact is off 3 2 1 3 Using 14 20 AWG wire make remote ON OFF connection from the Rear Panel Terminal marked REMOTE PORT to a remote control contact If the remote control contact is in low impedance short state the inverter will be turned ON and if the remote control contact is...

Page 10: ... positive is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently WARNING Do not connect the 12V model to a 24 battery The unit will be destroyed immediately 3 2 4 Chassis ground or to vehicle chassis using 8 AWG wire WARNING Operation of the inverter without a proper ground connection may result in an electrical safety hazard 8 ...

Page 11: ... not install the Inverter in a dusty environments where are dust wood particles or other filings shavings are present These dust can be pulled into the unit when the cooling fan is operating 3 3 6 Close to batteries Avoid excessive cable lengths but do not install the Inverter in the same compartment as batteries Use the recommended wire lengths and sizes see section 3 6 Also do not mount the Inve...

Page 12: ...of power inverter The red terminal is positive and black terminal is negative Insert the cables into the terminals and tighten screws to clamp the wires securely WARNING You may observe a spark when you make this connection since current may flow to charge capacitors in the power inverter Do not make this connection in the presence of Flammable fumes Explosion or fire may result WARNING Make sure ...

Page 13: ...N position and the buzzer will send out Beep sounds sounds at the moment the inverter will do self diagnosis and the LED s indicators will also appear various colors Finally the buzzer will send out another Beep sound and the Input Level LED indicators will turn to Green color and the inverter starts working successfully 3 4 6 Set the power switch to the OFF position the inverter stops and all the...

Page 14: ... AC sources such as inverter and generators have their neutral conductors tied to ground in the same way that the neutral conductor from the utility is tied to ground at the AC breaker panel For models configured with a transfer relay while AC utility power is presenting and the Inverter is in bypass mode this connection neutral of the Inverter s AC output to input safety ground is not present so ...

Page 15: ...ctrical shock hazard may result 3 6 Making DC Wiring Connections Follow this procedure to connect the battery cables to the DC input terminals on the Inverter Your cables should be as short as possible ideally less than 10 feet 3 meters and large enough to handle the required current in accordance with the electrical codes or regulations applicable to your installation Cables that are not an adequ...

Page 16: ...wing cables for optimum inverter performance apply both 120V and 230V versions Model No Wire AWG Inline Fuse S600 112 4 100A S600 212 4 100A S600 124 6 50A S600 224 6 50A Also use only high quality copper wiring and keep cable length short a maximum of 3 6 feet BATTERY INLINE FUSE S600 14 ...

Page 17: ...ds at once 3 7 1 Controls and indicators The ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the power inverter The Inverter operates from an input voltage ranging from 10 5 to 15 0 VDC for 12V models 21 0 to 30 0 VDC for 24V models 42 0 to 60 0 VDC for 48V models The Inverter will indicate high and low DC voltage conditions as follows Mod...

Page 18: ... blinked fast Over input voltage OVP Check input voltage Reduce input voltage b Fault level light is blinked slowly Low input voltage UVP Recharge battery Check connections and cable c Fault level light is blinked Intermittently Thermal shutdown OTP Improve ventilation Make sure ventilation openings in inverter are not obstructed Reduce ambient temperature d Fault level light is ON Short circuit o...

Page 19: ...ranty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally and does not cover damage arising from improper use such as plugging The unit into an unsuitable power sources attempts to operate products with excessive power consumption requirements or use in unsuitable environments This is the only warranty that the company makes No...

Page 20: ...7 1 CE LVD EN60950 Declaration of Conformity 18 ...

Page 21: ...7 2 FCC Class B Declaration of Conformity 19 ...

Page 22: ...7 3 e mark e13 020866 Declaration of Conformity 20 ...

Page 23: ...7 3 e mark e13 020866 Declaration of Conformity 21 ...

Page 24: ...7 4 UL UL458 NOTICE OF COMPLETION 22 YOUR S D y DISTRIBUTOR SOLIGENT 800 967 6917 www soligent net ...