TERMS OF WARRANTY

1. Warranty time begins with the invoice date and contains different time periods for different types of 
products.

2. All the defects and errors occured by Solimpeks during manufacturing process are under guarantee terms.
3. The products manufactured by Solimpeks have a limited time of repair under warranty terms, this limited 
repair time is 30 working days. 
4. The products imported or traded by Solimpeks are not under these warranty terms, Solimpeks just reflects 
the same warranty terms and conditions of the original supplier.
5. If the defects are not possible to repair, Solimpeks replaces the product with a new one. 
6. The defects and errors occured during the project process, installation, transportation and poor finishing are 
not under these warranty terms.
7. Solimpeks guarantess the collectors for a period of 10 years and  guarantees the boilers for 5 years.

INVALIDATES WARRANTY TERMS

1. The defects and errors during project, installation and poor finishing.
2. The defects and errors during transportation.
3. The defects and errors occured by and during open loop installation of the system, such as corrosion and 
freezing of the system.
4. The defects and errors occured by not protecting the system against freezing on the closed loop 
applicatons.
5. The defects and errors occured by mounting or repairing the system without the authorized dealer or 
service.
6. Breakage of the glass.
7. Natural disasters like fire, calamity, earthquakes,hail etc..
8. The defects and errors occured by incorrect usage from the consumer.
9. The defects and errors occured by antifreeze liquid leakages such as corrosion and sedimentation.
10. Chemical and physical damage caused by other equipment while installing the system.
11. Any defects and errors on the warranty letter such as an unconfirmed warranty letter or any ammendments 

and changes on it. 

MANUFACTURER COMPANY

Solimpeks Enerji San. ve Tic. A.Ş.
Konsan Organize Sannayi Hilal Sk. No: 20
42300 - Karatay/KONYA / TURKEY
Tel: 0332-444 06 02     /   Fax: 0332-444 06 08

www.solimpeks.com

/     

info@solimpeks.com

SELLER COMPANY

Date / Signature / Stamp

WARRANTY LETTER WILL BE SENT TO THE MANUFACTURER COMPANY

I have read and accepted all the warranty terms and conditions.

PRODUCT

Brand: 
Model:
Serial No :
Delivery date

CUSTOMER

Name / Surname:
Tel :
Address: 
………………………………………………….………………..

……………………………………………………….………..
………………………………………………………………...
………………………………………………………………….

Summary of Contents for Wunder CLS 1808

Page 1: ...Tel 903324440602Fax 903324440608 www solimpeks com info solimpeks com Solimpeks Solar Energy Systems Co Solarkeymark Registration No Wunder CLS models 011 7S292 F Wunder CNP models 011 7S480 F ITW Tes...

Page 2: ...Wunder is one of the most efficient products in its class it is based on Sol Titanium coated copper absorbers This absorber gets the best possible absorption of solar rays and also has a very low leve...

Page 3: ...of up to 650 C within the collector The insulation material must be of a high quality in order to withstand these high temperatures In addition this insulation material with its high density does not...

Page 4: ...of the sun Silicone is applied between the EPDM and glass Before assembling the expansion of the glass must be taken into consideration Therefore all the possible negative effects of expansion are neu...

Page 5: ...ze San Tic Merkezi Ankara Yolu 10 km Hilal Sok No 20 42300 Karatay Konya T rkiye Tel 903324440602 Fax 903324440608 www solimpeks com info solimpeks com WUNDER Case Dimensions COLLECTOR Type A B 1808 1...

Page 6: ...ropriate anti freeze use by the consumer when it is necessary to do so 6 The breakage of glass because of the external factors invalidates the guarantee 7 Any service by other than authorized personne...

Page 7: ...efects and errors occured by and during open loop installation of the system such as corrosion and freezing of the system 4 The defects and errors occured by not protecting the system against freezing...

Page 8: ...ng the collectors and other equipment to the installation point If the collectors are being pulled up by a rope collectors must be pulled up one by one Collectors must be pulled up in a fixed position...

Page 9: ...24 mm 18 mm 22 mm 24 mm 18 mm 22 mm 24 mm Header Tube Wall Thickness 0 70 mm 0 70 mm 0 70 mm 0 70 mm Number of Tubes 10 9 8 8 Tube pitch mm 110 mm 110 mm 110 mm 110 mm Glass Material Low Iron Tempered...

Page 10: ...mm 24 mm 18 mm 22 mm 24 mm 18 mm 22 mm 24 mm 18 mm 22 mm 24 mm Header Tube Wall Thickness 0 70 mm 0 70 mm 0 70 mm 0 70 mm Number of Tubes 10 9 8 8 Tube pitch mm 110 mm 110 mm 110 mm 110 mm Glass Mate...

Page 11: ...24 mm 18 mm 22 mm 24 mm 18 mm 22 mm 24 mm 18 mm 22 mm 24 mm Header Tube Wall Thickness 0 70 mm 0 70 mm 0 70 mm 0 70 mm Number of Tubes 10 9 8 8 Tube pitch mm 110 mm 110 mm 110 mm 110 mm Glass Materia...

Page 12: ...olimpeks Solar Enerji Sistemleri Konsan zel Organize San Tic Merkezi Ankara Yolu 10 km Hilal Sok No 20 42300 Karatay Konya T rkiye Tel 903324440602 Fax 903324440608 www solimpeks com info solimpeks co...

Page 13: ...r used in the collector can get the most efficient energy when it is mounted absolutely vertically to the Sun s rays The angle of the Sun s rays varies subject to hourly and seasonal changes Hence the...

Page 14: ...Sistemleri Konsan zel Organize San Tic Merkezi Ankara Yolu 10 km Hilal Sok No 20 42300 Karatay Konya T rkiye Tel 903324440602 Fax 903324440608 www solimpeks com info solimpeks com 3R 45 40 5D 2L 1L Cl...

Page 15: ...X 40 mm 2L 1 3 screwed pieces of 1490 1190 980 X 40 X 40 mm 3R 1 2 screwed pieces of 1670 X 30 X 5 mm 5U 1 2300 X 30 X 30 mm 5D 1 2300 X 30 X 30 mm Screw 19 M10 X 20 Nut 19 M10 Clips 4 90 X 30 1 Colle...

Page 16: ...inum profile dimensions mm Model 1 coll 2 coll 2510 1335 x 30 x 30 2670 x 30 x 30 2108 1150 x 30 x 30 2300 x 30 x 30 2008 1150 x 30 x 30 2300 x 30 x 30 1808 1050 x 30 x 30 2100 x 30 x 30 Part Name Qua...

Page 17: ...Z Support 4 4 2 8 x 60 Wood Screw 18 18 3 M10 x 25 Screw 12 14 4 M10 Nut 12 14 5 Clips 2 4 6 Tank holder 2 2 7 2450 X 40 X 40 mm 1 1 8 2450 X 40 X 40 mm 1 1 9 Aluminum profile 1 1 10 Aluminum profile...

Page 18: ...Solimpeks Solar Enerji Sistemleri Konsan zel Organize San Tic Merkezi Ankara Yolu 10 km Hilal Sok No 20 42300 Karatay Konya T rkiye Tel 903324440602 Fax 903324440608 www solimpeks com info solimpeks c...

Reviews: