Getting Started

1. Download the software from: www.solinst.com/downloads 

and install Levelogger Software on your PC.

2. Install the Wellhead batteries. The Wellhead uses 4 user-

replaceable 1.5V AA lithium batteries. 

3. Connect the Wellhead and logger to the Vented Cable: 

Support 

Hanger 

Bracket

- 2 -

Note:

 See page 6 for instructions to install the Support Hanger 

Bracket, as shown at right.

Note: 

For information on using your AquaVent logger with  

 

MODBUS or SDI-12 protocols, see separate User Guides.

Battery  

Compartment

SP  

Wellhead

Vented 

Cable

AquaVent 

Logger

10-Pin (SP) 

Connection

Alignment socket in the 

Vented Cable connectors

Alignment pin in the Wellhead 

and logger connectors

Coupling

Connector 

Body

Line up the alignment socket in the Vented Cable connector with the 

alignment pin in the Wellhead connector. 

Carefully 

push the connectors together. Twist the cable connector 

slightly

 until you will feel a 

small click

 when the properly aligned 

connection is made. 

Tighten the stainless steel coupling while holding the stainless steel cable 

connector body still. Tighten the coupling until it seats. 

Do not twist the 

Vented Cable or Wellhead. 

Follow the same procedure when connecting the logger to the Vented 

Cable. 

Well Cap 

Base

Summary of Contents for AquaVent 3500

Page 1: ...High Quality Groundwater and Surface Water Monitoring Instrumentation Quick Start Guide 3500 AquaVent Please read this document carefully before using the AquaVent...

Page 2: ...Wellhead Vented Cable AquaVent Logger 10 Pin SP Connection Alignment socket in the Vented Cable connectors Alignment pin in the Wellhead and logger connectors Coupling Connector Body Line up the alig...

Page 3: ...gger Settings Window Note Clicking on the embedded in the software will provide you with a short explanation of that feature e g Com Port Slate Mode Time Synchronization etc Starting and Stopping Aqua...

Page 4: ...view rate is set independently of the logging period of the AquaVent and does not interfere with internal logging taking place To take a reading at any specific time click and that reading will be add...

Page 5: ...reference datum in the Manual Data Adjustment option in the Software Data Wizard AquaVent loggers detect both water W and barometric pressure B However a vent tube to surface allows barometric effect...

Page 6: ...g 4 using an adaptor However other installations are acceptable if proper precautions and recommendations are followed Leave at least 2 50 mm of slack in the Vented Cable at surface to allow you to li...

Page 7: ...ing blue red USB connection has been dropped Flashing yellow The Wellhead is communicating with the PC Software Maintenance As with any monitoring project you should select the proper equipment and de...

Page 8: ...e bottom of the battery holder 2 Check the Vented Cable connections to the AquaVent logger and Wellhead Ensure they are lined up correctly and there is no dirt or debris in the connection 3 Make sure...

Reviews: