Remote Radio Link User Guide
Page 7
Figure 2-8 Splitter (pt# 109427)
Figure 2-9 Splitter Connection
2.2.3 Connecting AquaVent Dataloggers
AquaVent dataloggers are connected to the station using a Reader Cable connected to an AquaVent Wellhead
Connector Cable, which is connected to the Aquavent Wellhead (which is connected to the AquaVent Vented
Cable and Datalogger).
Note:
For more information on installing AquaVent dataloggers in the field, see the Vented Dataloggers User Guide.
Figure 2-7 Connecting AquaVent Dataloggers
AquaVent Wellhead
Connector Cable
(Connect to Reader
Cable)
Reader Cable
AquaVent Wellhead
Vented Cable
2.2.4 Splitters
Splitters allow the connection of up to four dataloggers to each RRL Station. One or two Splitters can be used,
each allowing the connection of two dataloggers. To connect a Splitter to the RRL Station, remove the black
dust cap line up the holes in the connectors and screw the Splitter onto the RRL connection until finger-tight.
Reader Cables are connected to the Splitters in the same manner they are connected directly to the RRL
Station.